PAIR IDENTIFICATION

PAIR IDENTIFICATION

Receiver Setup

Connect the inductive probe to the Receiver accessory jack using the probe cable.

Press OPTIONAL ACCESSORIES to turn the Receiver on.

Press Manual background to select the 33 kHz frequency.

Insert the Probe into the bundle of pairs (or the group, if known) and

press Manual background. Next, divide the pairs into two bundles and insert the

Probe into each of the bundles and observe the numeric display. The bundle with the highest reading will contain the target pair. Continue by dividing the bundle with the target pair into two parts and checking each part for the highest signal. In this way the pair to be identified will be isolated.

OPTIONAL ACCESSORIES

1196 6- inch Dyna-Coupler (includes Pouch)

2205 EMS Marker Locating Accessory (single frequencies)

2206 EMS Marker Locating Accessory (all frequencies)

3005 1 inch Dyna-Coupler

3011 Inductive Probe

3019 3 inch Dyna-Coupler Kit (includes 9011 Coupler Cable and Pouch) 3229 Active Duct Probe (sonde)

9011 Coupler Cable

9023 Probe Cable

9043 Ground Extension Cable