PAIR IDENTIFICATION
Receiver Setup
Connect the inductive probe to the Receiver accessory jack using the probe cable.
Press to turn the Receiver on.
Press to select the 33 kHz frequency.
Insert the Probe into the bundle of pairs (or the group, if known) and
press . Next, divide the pairs into two bundles and insert the
Probe into each of the bundles and observe the numeric display. The bundle with the highest reading will contain the target pair. Continue by dividing the bundle with the target pair into two parts and checking each part for the highest signal. In this way the pair to be identified will be isolated.
OPTIONAL ACCESSORIES
1196 6- inch
2205 EMS Marker Locating Accessory (single frequencies)
2206 EMS Marker Locating Accessory (all frequencies)
3005 1 inch
3011 Inductive Probe
3019 3 inch
9011 Coupler Cable
9023 Probe Cable
9043 Ground Extension Cable
Page 13