Section 3.
Installation When Attaching to a Static Control Work Surface
Fig. 3
The Model 725 Monitor can be used to ground a work surface while providing a monitored grounding point for an operator. To ground a work surface, the Model 725 Monitor contains a snap located on its bottom cover, that is connected internally to the monitor’s ground cord. To use this feature there must be a female (10 mm) snap fastener attached to the grounding layer of the work surface. Simply align the male snap on the monitor with the female snap on the work surface and press downward on the monitor. The work surface is now automatically grounded through a one megohm resistor by the Model 725 Monitor.
Note:
Although the work surface is grounded by the Model 725 Monitor, it is not monitoring the ground to the work surface.
3M™ 8200 Series Work Surfaces use the female 10 mm (3M™ Model 3050) snap fastener for grounding. 3M™ 1800, 8300, and 8800 Series Work Surfaces use the female 10mm (3M™ Model 3034) snap fastener for grounding. In addition all 3M™ 8500 Series Portable Field Service Kits include the 10 mm (3M Model 3034) snap fastener.
Use of an optional 3M™ 3057 Stand- By Jack at the work station extends the life of the monitor’s input jack. The user disconnects the wrist strap ground cord from the wrist band
and plugs into the 3057 jack which is mounted at the work station. Plugging into the 3057 jack prevents the Model 725 from continuously alarming when disconnected
from the wrist band.
The system is now ready for use.
6