3M MP8640 manual Maintenance, Cleaning the Air Filter, Message Table

Models: MP8640

1 28
Download 28 pages 35.6 Kb
Page 23
Image 23
Section 6: Maintenance

Section 6: Maintenance

6.1 Cleaning the Air Filter

Note: Clean the air filter about every 50 hours.

a)Turn off the MAIN POWER switch of the projector and pull out power cord. Let cool for 20 minutes.

b)Remove the air filter from the bottom of projector. Unscrew two retaining screws and pull down and out on the handle to free air cleaner door. Carefully lift up and out on filter door.

Remove the air filter

c)Clean the air filter using a vacuum cleaner. If dirt is still present, wipe the air filter with a cloth moistened with water and wipe with a dry lint-free cloth.

d)After filter dries completely, re-install the air filter.

Note: If air flow is restricted due to dust accumulation on filter, the projector may shut down due to over heating.

6.2Message Table

a)On Screen Display. The following messages are displayed on the screen:

NO SIGNAL IS DETECTED: The projector is not detecting a signal.

SYNC IS OUT OF RANGE: The horizontal frequency of the input signal exceeds the range

of the projector, or it cannot be displayed.

CHANGE THE LAMP:Change when the lamp message appears on the screen. See Section 6.3 for more information.

b)Indicator Display. The ON indicator, LAMP indicator and TEMP indicator will light or blink in the following cases:

 

Indicator status

Meaning

Remedy

 

 

 

 

 

Lights orange

Standby mode

normal

 

 

 

 

ON indicator

Blinks green

During warming up

normal

 

 

 

Lights green

During operation

normal

 

 

 

 

 

 

Blinks orange

During cooling down

normal

 

 

 

 

LAMP indicator

Lights red

Lamp cannot light

Cool projector by power off for 20 minutes.

 

 

 

Blinks red

Air filter open

Ensure filter is closed.

 

 

 

 

 

TEMP indicator

Lights red

Temperature inside too high

Let projector cool 20 minutes. Check air flow and filter.

 

 

 

Blinks red

Cooling fan not operating

call your dealer

 

 

 

 

 

*When the LAMP indicator lights or blinks, turn the power off. If the problem persists, contact your dealer.

© 3M 1997

3MMultimedia Projector MP8640

23

Page 23
Image 23
3M MP8640 manual Maintenance, Cleaning the Air Filter, Message Table