A&D Ambulatory Blood Pressure Monitor instruction manual Air socket

Models: Ambulatory Blood Pressure Monitor

1 36
Download 36 pages 58.33 Kb
Page 8
Image 8

Yellow mark

Shoulder band

Air hose

 

Battery cover

 

Auto ON/OFF key

Adult cuff

for left arm

Start Stop key

 

S

 

ST

TA

RT

OP

 

 

O

A

 

 

 

 

U

 

 

N/

 

T

 

 

O

 

O

 

 

 

FF

0

0

1

 

 

 

1

 

2

 

3

 

2

 

 

 

 

4

 

 

 

 

5

6

 

 

 

 

Air hose plug

 

 

SY

 

 

 

 

DI S/

 

 

 

PU

A

I

 

 

 

 

NT

 

 

LS

 

ER

Air socket

 

 

TI

VAL

 

 

E/

ME

AIR

 

 

 

 

7

 

 

 

 

 

8

9

 

 

 

 

 

 

 

 

Carrying case

 

 

 

 

Reset key

Belt

 

 

 

ON

 

 

 

 

Power switch

 

 

 

 

OFF

 

 

 

 

 

RS-232C terminal

 

Alkaline batteries (type LR6, type AA, Mignon)

The batteries are not included in this pack.

 

Name

 

Functions

 

 

 

 

 

 

Power switch

 

This is the main power switch. In the OFF state, all data and

 

 

 

 

 

parameters are preserved by an backup battery. The backup

 

 

 

battery life is approximately 10 days with the power off.

 

 

 

 

 

 

AUTO ON/OFF

 

 

 

AUTO ON/OFF key

 

• When you press and hold the

 

key, the automatic

 

 

 

measurement is started or stopped alternately.

 

 

 

• When you press the

AUTO ON/OFF

key at mode II of the

 

 

 

automatic measurement, "S" is displayed or turned off alter-

 

 

 

nately. This sign changes the interval for sleep.

 

 

 

 

START STOP

 

 

 

 

 

 

START STOP key

 

• When you press the

 

key, a blood pressure mea-

 

 

 

surement is started at once.

 

 

 

 

 

 

 

 

• When you press and hold the

START STOP

key for approx. 3

 

 

 

seconds, the recorder proceeds to "Selection for the auto-

 

 

 

matic measurement".

 

 

 

 

 

 

 

 

• When you press and hold the

START STOP

key for approx. 6

 

 

 

seconds, the recorder proceeds to "Parameters for the display

 

 

 

and clock".

 

 

 

 

 

 

 

 

• When you press and hold the

START STOP

key for approx. 9

 

 

 

seconds, the recorder proceeds to "Deleting old data".

 

RS-232C terminal

 

This terminal is used for data output to a printer or computer.

 

 

 

 

 

The optional RS-232C cable is necessary to output the data.

 

Reset key

 

All data and parameters are deleted.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Packing List and Component Names

Page 6

Product overview

Page 8
Image 8
A&D Ambulatory Blood Pressure Monitor instruction manual Air socket

Ambulatory Blood Pressure Monitor specifications

The A&D Ambulatory Blood Pressure Monitor is a cutting-edge device designed for the accurate measurement of blood pressure over an extended period. This innovative tool is particularly beneficial for diagnosing hypertension and evaluating blood pressure variability, making it essential for both healthcare professionals and patients.

One of the main features of the A&D Ambulatory Blood Pressure Monitor is its ability to perform measurements during the patient’s normal daily activities. This is crucial for capturing accurate readings, as blood pressure can fluctuate significantly throughout the day due to various factors such as stress, physical activity, and diet. By documenting blood pressure readings at set intervals over 24 hours, this monitor provides a comprehensive overview of the patient's cardiovascular health.

The device utilizes advanced oscillometric technology, which enhances accuracy by analyzing the oscillations in the arterial wall during cuff inflation. This method is recognized for its reliability compared to traditional auscultatory techniques. The monitor is equipped with a large memory capacity, allowing it to store numerous readings which can be analyzed later. This feature is invaluable for doctors who need to review the patient’s blood pressure patterns over time.

User-friendliness is another hallmark of the A&D Ambulatory Blood Pressure Monitor. The device typically features an intuitive display and controls that make it easy to navigate through settings and review stored data. Many models offer wireless connectivity, enabling seamless data transfer to smartphones or computers for further analysis and reporting. This capability aids healthcare providers in timely decision-making regarding treatment options.

Additionally, the A&D monitor is designed with comfort in mind. It comes with a soft, adjustable cuff that can accommodate a range of arm sizes, ensuring an accurate fit and comfortable experience for the patient. The device is ergonomically designed and lightweight, making it easy to wear throughout the day without interfering with daily activities.

The A&D Ambulatory Blood Pressure Monitor not only promotes better patient compliance but also enhances clinical outcomes by enabling continuous and accurate monitoring of blood pressure in real-world settings. Overall, this device embodies the convergence of technology and healthcare, providing invaluable data that fosters informed decisions and improves patient care.