is

3 Installation

Warning

Installation work should be carried out by an approved installation engineer in compliance with the general and local regulations imposed by the gas, water and power supply companies and the fire service.

The appliance may only be installed in a room that complies with the requirements stated in national and local ventilation

regulations (1.3 "Regulations").

3.1

Introduction

This chapter describes the installation activities to be carried out before you

 

 

actually start using the appliance (9 "Starting and running"), namely:

 

 

Packaging;

 

 

Environmental conditions;

 

 

Technical specifications;

 

 

Water connections, Unvented;

 

 

Water connections, Vented;

 

 

Gas connection;

 

 

Air supply and flue;

 

 

Electrical connection;

 

 

Checking the supply pressure and burner pressure;

In the event of conversion to a different gas category, see conversion (4 "Conversion to a different gas category").

3.2

Packaging

To avoid damaging the appliance, remove the packaging carefully.

 

 

We recommend unpacking the appliance at or near its intended location.

 

 

 

 

 

Attention

 

 

The appliance may only be manoeuvred in an upright position. Take care

 

 

that the appliance is not damaged after unpacking.

3.3

Environmental

 

The appliance is suitable for either open or room-sealed combustion. If

 

conditions

installed as a room-sealed appliance, then the availability of the necessary

external air supply will depend on the place of installation. In this event, there are no additional ventilation requirements.

If the appliance is to be installed as an open system, then it will be subject to the guidelines and ventilation regulations that are in force locally.

The alternative installation types are B23, C13, C33, C43, C53 and C63.

Attention

The appliance may not be used in rooms where chemical substances are stored or used, due to the risk of explosion and/or corrosion of the appliance. Some propellants, bleaching agents, degreasing agents etc. disperse vapours which are explosive and/or which cause accelerated corrosion. If the appliance is used in a room in which such substances are present, the warranty will be void.

Instruction manual BFC

17

Page 17
Image 17
A.O. Smith BFC - 30, BFC - 60 service manual Installation, Packaging, Environmental, Conditions

BFC - 30, BFC - 60 specifications

A.O. Smith is a well-regarded name in the water heating industry, known for producing innovative and efficient water heaters. Among their renowned products are the BFC - 60 and BFC - 30 models, which have gained popularity for their performance and reliability.

The A.O. Smith BFC - 60 and BFC - 30 are both designed to meet the diverse needs of residential and commercial users. The BFC - 60 has a capacity of 60 gallons, making it ideal for larger households or commercial settings where hot water demand is high. Meanwhile, the BFC - 30, with its 30-gallon capacity, caters to smaller households or establishments with lower hot water requirements.

One of the standout features of both models is their advanced heating technology. They are equipped with a high-efficiency burner system, which enhances the heating process while minimizing energy consumption. This means that users experience quicker recovery times and can enjoy a steady supply of hot water without the long wait associated with traditional heaters. The BFC series is designed to save energy, aligning with modern demands for sustainability.

Another significant characteristic of these models is their durable construction. Made with high-quality materials, including glass-lined tanks, they are built to resist corrosion and extend the lifespan of the water heater. This durability contributes to fewer maintenance requirements, giving users peace of mind.

In terms of safety, A.O. Smith has incorporated numerous features into the BFC series. Both models come with safety valves and thermostat controls to ensure that water is heated to appropriate temperatures, reducing the risk of scalding and malfunction. Additionally, their design allows for easy installation and maintenance, making them a user-friendly option.

Another aspect that distinguishes the BFC series is its compact design. Both models have a space-saving profile, making them suitable for installation in various locations, including tight utility rooms or basements. This flexibility allows homeowners and businesses to maximize their space without sacrificing performance.

Overall, the A.O. Smith BFC - 60 and BFC - 30 are exemplary water heating solutions that combine efficiency, durability, and safety. With their advanced features and technologies, they are an excellent choice for anyone in need of reliable hot water, ensuring comfort and satisfaction for years to come.