A.O. Smith BFC - 30, BFC - 60 service manual Week program setting the switch- on time

Models: BFC - 30 BFC - 60

1 98
Download 98 pages 30.7 Kb
Page 61
Image 61

gis

The display shows the menu for the week program, see the figure below. With the default setting, the program switches on and off every day at 00:00 and 23:59 hours respectively, the water temperature is 65°C and the pump is switched on (P).

 

DAY TIME Tset

ON »SU

00:00 65ÉC P

OFF SU

23:59

ON

MO

00:00 65ÉC P

 

 

 

OFF

MO

23:59

ON

TU

00:00 65ÉC P

OFF

TU

23:59

ON

WE

00:00 65ÉC P

OFF

WE

23:59

ON

TH

00:00 65ÉC P

OFF

TH

23:59

ON

FR

00:00 65ÉC P

OFF

FR

23:59

ON

SA

00:00 65ÉC P

OFF SA

23:59

 

INSERT

DELETE

START OPERATION

Example

As an example, we will set the switch-on time for Sunday to 08:15 hours, and the matching switch-off time to 12:45 hours. The water temperature will be set to 75 °C and the pump will run continuously.

The following settings are entered one by one via the menu: the switch-on time, the switch-off time, the desired water temperature, and the mode of the program-controlled pump.

11.7.1Week program: setting the switch- on time

1.Bring the cursor to SU

Confirm with .

ON

»SU 00:00

 

OFF

SU 23:59

 

Tset

65ÉC

 

PUMP

ON

SAVE

 

 

 

The day indicated by » flashes.

2.Use and to set the desired day. In the example this is SU (Sunday).

Confirm with .

ON

SU»00:00

 

OFF

SU 00:59

 

Tset

65ÉC

 

PUMP

ON

SAVE

 

 

 

The cursor moves to the hour digits, which flash.

3.Use and to set the hours. In the example, this is 08.

Confirm with .

The cursor moves to the minute digits, which flash.

ON

SU 08»00

 

 

OFF

SU 08:00

 

 

Tset

65ÉC

 

 

PUMP

ON

SAVE

 

 

 

 

 

Note

Because the switch-off time can never be earlier than the switch-on time, the switch-off time setting is automatically adjusted with the switch-on time.

4.Use and to set the minutes. In the example, this is 15.

Confirm with .

The cursor moves to the switch-off hour digits, which flash.

ON

SU 08:15

 

OFF

SU»08:15

 

Tset

65ÉC

 

PUMP

ON

SAVE

 

 

 

11.7.2Week program: setting the switch- off time

1.Use and to set the hours. In the example, this is 12.

Confirm with .

The cursor moves to the minute digits, which flash.

ON

SU 08:15

 

OFF

SU 12»15

 

Tset

65ÉC

 

PUMP

ON

SAVE

 

 

 

2.Use and to set the minutes. In the example, this is 45.

Confirm with .

The cursor moves to the desired water temperature.

ON

SU 08:15

 

OFF

SU 12:45

 

Tset»65ÉC

 

PUMP

ON

SAVE

 

 

 

11.7.3Week program: setting the water temperature

1.Use and to set the water temperature. In the example this is 75°C.

Confirm with .

The cursor moves to PUMP ON

ON SU 08:15

OFF SU 12:45

Tset 75ÉC

PUMP»ON SAVE

Instruction manual BFC

61

Page 61
Image 61
A.O. Smith BFC - 30, BFC - 60 Week program setting the switch- on time, Week program setting the switch- off time