TROUBLESHOOTING WITH THE LED

TROUBLESHOOTING WITH THE LED

 

LED STATUS

INDICATES

 

CHECK/REPAIR

 

OFF

No power to system control.

 

1.

Appliance On/Off switch in the Off position.

 

 

 

 

2.

Line voltage input power at L1 and L2 connectors.

 

 

 

 

3.

System wiring harness in good condition and securely

 

 

 

 

 

connected at both ends.

 

 

 

 

 

 

BRITE - DM

Normal Operation

 

Not Applicable.

 

 

 

 

 

 

 

This indication shows whenever the system is

 

 

 

 

 

powered, unless some abnormal event has occurred.

 

 

 

 

 

 

 

 

 

 

1 FLASH

Setpoint error, internal failure detected.

 

1.

Replace control.

 

 

 

 

 

 

 

 

 

 

 

Airflow proving switch remains open longer than

 

1.

Airflow proving switch stuck closed.

 

 

30 seconds after a call for heat begins.

 

2.

Airflow proving switch mis-wired or jumpered.

 

2 FLASHES

 

 

 

 

 

 

Combustion air blower is not energized

 

 

WARNING

 

 

until airflow proving switch opens.

 

 

Line Voltage Hazard.

 

 

 

 

 

Can cause property damage, severe injury or

 

 

 

 

 

death.

 

 

 

 

 

Turn off appliance before coming in contact with

 

 

 

 

 

pressure switch and/or electrical connections.

 

 

 

 

 

 

 

3 FLASHES

Airflow proving switch remains open longer than

 

1.

Airflow proving switch operation, tubing and wiring.

 

 

30 seconds after combustion air blower energized.

 

2.

Obstructions or restrictions in appliance air intake

 

 

 

 

 

or exhaust flue system that prevent proper combustion

 

 

System goes into 5 minute delay period, with

 

 

air flow.

 

 

combustion air blower off. At the end of the

 

 

 

 

 

5 minute delay, another ignition cycle will begin.

 

 

WARNING

 

 

 

 

 

Line Voltage Hazard.

 

 

 

 

 

Can cause property damage, severe injury or

 

 

 

 

 

death.

 

 

 

 

 

Turn off appliance before coming in contact with

 

 

 

 

 

pressure switch and/or electrical connections.

 

 

 

 

 

 

 

 

Thermal Cutoff open.

 

1.

Replace Control.

 

4 FLASHES

Combustion air blower is energized.

 

 

 

 

 

Internal hardware failure.

 

 

 

 

 

 

 

 

 

 

 

Flame signal sensed out of proper sequence.

 

1.

Flame at main burner.

 

5 FLASHES

Combustion air blower is energized.

 

2.

Replace control.

 

 

 

 

 

 

 

 

System Lockout.

 

1.

Gas supply off or at too low pressure to operate.

 

 

 

 

2.

Damaged or broken HSI element.

 

6 FLASHES

After 1 hour lockout reset delay, control will reset

 

3.

Appliance not properly earth grounded.

 

 

and initiate a new ignition sequence if the call for

 

4.

Flame sense rod contaminated or in incorrect location.

 

 

heat is still present.

 

5.

HSI element located incorrect position.

 

 

 

 

6.

HSI element or flame sense rod wiring in good

 

 

 

 

 

condition and properly connected.

 

 

 

 

7.

Less than 100 Vac between flame rod and burner

 

 

 

 

 

pan with 120 Vac input to control.

 

 

 

 

8.

Cycle external power or remove request for heat for

 

 

 

 

 

2 seconds and reapply.

 

 

 

 

 

 