1.3.2 Technical data

device category: II2H3+

 

 

 

 

 

 

DESCRIPTION

 

unit

BTI 85

BTI 100

 

 

 

 

DATA NATUREL GAS G20 - 20 mbar

 

 

 

Nominal capacity

 

kW

19.2

20.4

Nominal load (gross)

 

kW

25.1

26.7

Supply

pressure

 

mbar

20

20

Burner

pressure

 

mbar

12.0

7.9

Gas consumption *

 

m3/h

2.40

2.50

Diameter main orifice

 

mm

3.90

4.50

Diameter pilot orifice

 

mm

0.56 / 0.41

0.56 / 0.41

Heating time ΔT= 45K

 

min

46

58

DATA BUTANE G30 - 30 mbar

 

 

 

Nominal load (gross)

 

kW

24.5

26.0

Nominal capacity

 

kW

19.2

20.4

Supply

pressure

 

mbar

30

30

Gas consumption *

 

kg/h

1.8

1.9

Diameter main orifice

 

mm

2.30

2.35

Diameter pilot orifice

 

mm

0.23

0.23

DATA PROPANE G31 - 37 mbar

 

 

 

Nominal heat input (upper valvue)

kW

22.9

24.9

Output

 

 

kW

17.9

19.5

Inlet pressure

 

mbar

37

37

Gas consumption *

 

kg/h

1.6

1.8

Diameter main orifice

 

mm

2.30

2.35

Diameter pilot orifice

 

mm

0.23

0.23

GENERAL

 

 

 

 

Storage

capacity

 

litres

278

372

Water connections**

 

-

1-11.5 NPT

11/4-11.5 NPT

Gas connection

 

-

Rp1/

Rp1/

 

 

 

 

2

2

Drain valve

 

-

3/ "-14NPT

3/ "-14NPT

 

 

 

 

4

4

Anode

 

 

-

3/ "-14NPT

3/ "-14NPT

 

 

 

 

4

4

T&P plug

 

-

3/ "-14NPT

3/ "-14NPT

 

 

 

 

4

4

Maximum operating pressure

 

bar

8

8

Empty weight

 

kg

122

149

*Gas consumption at 1013,25 mbar and 15 °C

**For a leak proof sealed connection European coupling pieces can be used on the NPT connection nipples with a pipe thread of ISO 228/1