SIP IP Phone Models 480i, 480i CT, 9112i, 9133i Release Notes

 

Issues Resolved in Release 1.4.1

 

 

 

 

Issue Number

Description of Fix

 

 

DEF04757

The call transfer (Xfer) function was not working with Broadsoft SCA using multiple

 

headers. The call transfer now works on an SCA line with Broadsoft R13.

DEF05117

If the CODEC negotiation fails during the processing of a re-INVITE, the phone no

 

longer drops the call, but instead responds with a “488 Not Acceptable Here”

 

message.

 

 

Enhancements/Changes

 

This section describes the enhancements and changes made to the 1.4.1 release..

 

 

 

 

 

 

 

 

 

Note: Unless specifically indicated, these enhancements apply to all

 

 

 

 

 

 

 

 

phone models.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Issue Number

 

 

 

Description of Fix

 

 

 

 

 

DEF04638

 

 

 

XML URIs now support adding a port number to the URI.

 

 

 

 

 

ENH04358

 

 

 

Added ability to change debug level from Aastra Web UI. You can now configure a

 

 

 

 

“log level” in the Troubleshooting section of the Web interface.

 

 

 

 

 

ENH04371

 

 

 

Web recovery now resets the administrator password and removes local

 

 

 

 

configuration files. You force the phone into recovery mode by holding ‘#’ and ‘1’ on

 

 

 

 

startup.