Lexicon, Inc.

 

 

 

 

DC-2/MC-1 Serial Communications Protocol

 

Printed on: 10/19/00

 

 

 

 

Application Header:

 

 

 

Command

DC_CMD_GET_INPUT_NAME

0x2D

 

Data Count

1

 

0x01

 

Application Data:

 

 

 

Data[0]

InputId

 

nn

 

7.3.13.2 Data Description

 

 

InputId:

 

 

 

 

Data Type:

Unsigned 8 bit Integer

 

 

Max Value:

7

 

 

Conversion:

Input Id are defined in Appendix D Input Id’s

7.3.13.3 Data Validation:

The InputId must be a valid Input number. If it is not the DC-2/MC-1 will respond with a NAK packet and error code DC_ERR_ INVALID_INPUT_ID.

7.3.13.4 Input Name Response Packet

Application Header:

Command

DC_RESP_INPUT_NAME

0x8A

Data Count

strlen(InputName) + 2

nn

Application Data:

 

 

Data[0]

InputId

nn

Data[2]- Data[DataCount-1]

InputName

ch ch ch … 0x00

7.3.13.5 Data Description

InputId:

 

Data Type:

Unsigned 8 bit Integer

Max Value:

7

Conversion:

Input Id’s are defined in Appendix D Input Id’s

InputName:

 

Data Type:

Null(0x00) terminated ASCII character string.

Max Length:

INPUT_NAME_LENGTH defined in Appendix E Protocol Constants.

7.3.14 Get FPD Control Registers

Request to DC-2/MC-1 for FPD control registers. DC-2/MC-1 will respond with “FPD Control Register Packet”.

7.3.14.1 Command Packet Description

Application Header:

 

Command

DC_CMD_GET_FPD_CONTROL

0x29

Data Count

0

0x00

Application Data:

 

 

N/A

 

7.3.14.2 FPD Control Register Response Packet

22 of 44

Page 22
Image 22
ABC Office MC-1, DC-2 manual Get FPD Control Registers, Input Name Response Packet, FPD Control Register Response Packet