Lexicon, Inc.

 

 

DC-2/MC-1 Serial Communications Protocol

Printed on: 10/19/00

Zone 2 Balance

Z2_BAL

 

Zone 2 Mute

Z2_MUTE

 

Bass

BASS

 

Treble

TREBLE

 

Loudness

LOUDNESS

 

Tilt

TILT

 

Menu Background On/Off

MENU_BKGND

 

The parameter definitions for each of these parameters can be obtained by querying the DC-2/MC-1 with the DC_CMD_GET_SYS_PARAM_BY_NAME command. The DC_RESP_SYS_PARAM_DEF will contain the ParamId for each of the parameters. The ParamId may change with s/w version changes, but the Parameter Name will not.

7.2 Acknowledgment Packets

Acknowledge and No Acknowledge packets are used to communicate transmission, packet and data validation status. Both the HOST and DC-2/MC-1 can transmit and receive these packets.

7.2.1

Acknowledge

 

 

 

 

7.2.1.1

Packet Description

 

 

 

 

 

 

 

 

 

 

Application Header:

 

 

 

 

Command

 

DC_ACK

 

0xE0

 

Data Count

 

 

1

0x01

 

Application Data:

 

 

 

 

 

Data[0]

 

Command

 

nn

 

7.2.1.2

Data Description

 

 

 

 

Command:

 

 

 

 

 

 

 

DataType:

Valid DC-2/MC-1 command as defined in Appendix A Command Codes.

7.2.2 No Acknowledge

 

 

 

 

7.2.2.1

Packet Description

 

 

 

 

 

 

 

 

 

Application Header:

 

 

 

 

Command

DC_NACK

0xE1

 

 

Data Count

 

2

0x02

 

 

Application

Data:

 

 

 

 

 

Data[0]

Command

nn

 

 

Data[1]

ErrorCode

nn

 

 

7.2.2.2 Data Description

Command:

 

DataType:

Valid DC-2/MC-1 command as defined in Appendix A Command Codes.

ErrorCode:

 

DataType:

Error code as defined in Appendix B Error Codes.

10 of 44