| 67 |
|
|
Error Messages | Corrective Action |
|
|
02B2 Incorrect Drive A | Type of floppy drive A: not correctly identified in |
type - run SETUP | Setup. |
|
|
02B3 Incorrect Drive B | Type of floppy drive B: not correctly identified in |
type - run SETUP | Setup. |
|
|
02D0 System cache | RAM cache failed and BIOS disabled the cache. |
error - Cache disabled | On older boards, check the cache jumpers. You |
| may have to replace the cache. See your dealer. A |
| disabled cache slows system performance |
| considerably. |
|
|
02F0: CPU ID: | CPU socket number for |
|
|
*02F4: EISA CMOS not | ServerBIOS2 test error: Cannot write to EISA |
writeable | CMOS. |
|
|
*02F5: DMA Test Failed | ServerBIOS2 test error: Cannot write to extended |
| DMA (Direct Memory Access) registers. |
|
|
*02F6: Software NMI | ServerBIOS2 test error: Cannot generate |
Failed | software NMI |
|
|
*02F7: | ServerBIOS2 test error: |
NMI Failed | long. |
|
|
device Address Conflict | Address conflict for specified device. |
|
|
Allocation Error for: | Run ISA or EISA Configuration Utility to resolve |
device | resource conflict for the specified device. |
|
|
*Failing Bits: nnnn | The hex number nnnn is a map of the bits at the |
| RAM address which failed the memory test. Each |
| 1 (one) in the map indicates a failed bit. See |
| errors 230, 231, or 232 above for offset address of |
| the failure in System, Extended, or Shadow |
| memory. |
|
|
Invalid System | Problem with NVRAM (CMOS) data. |
Configuration Data |
|
|
|
I/O device IRQ conflict | I/O device IRQ conflict error. |
|
|