1. Product Specification (continued)

ACER X193HQ

 

7

 

 

 

Go to cover page

1.4.5.5 Defect Terminology

1.5 Optical Characteristics

Table 3 gives the descriptive terms used in classifying

Depends on the LCD supplier's spec. Details refer to QA

defects.

 

Inspection Spec.

 

 

 

 

S p o t s o r l i n e s t h a t a p p e a r d a r k i n t h e d i s p l a y p a t t e r n s a n d a r e

 

 

u s u a l l y t h e r e s u l t o f c o n t a m i n a t i o n . D e f e c t s d o n o t v a r y i n

 

D a r k / S p o t s / L i n e s

s i z e o r i n t e n s i t y ( c o n t r a s t ) w h e n c o n t r a s t v o l t a g e i s v a r i e d .

 

 

C o n t r a s t v a r i a t i o n c a n b e a c h i e v e d t h r o u g h t h e u s e o f v a r y i n g

 

 

g r a y s h a d e p a t t e r n s .

 

 

S p o t s o r l i n e s t h a t a p p e a r l i g h t i n t h e d i s p l a y p a t t e r n s .

 

B r i g h t S p o t s / L i n e s

D e f e c t s d o n o t v a r y i n s i z e o r i n t e n s i t y ( c o n t r a s t ) w h e n

 

c o n t r a s t v o l t a g e i s v a r i e d . C o n t r a s t v a r i a t i o n c a n b e a c h i e v e d

 

 

 

 

t h r o u g h t h e u s e o f v a r y i n g g r a y s h a d e p a t t e r n s .

 

 

 

 

 

W h e n t h e u n i t l i g h t s , l i n e s a p p e a r l i g h t ( w h i t e ) w i t h d i s p l a y

 

P o l a r i z e r S c r a t c h

p a t t e r n s d a r k a n d d o n o t v a r y i n s i z e . P h y s i c a l d a m a g e t o t h e

 

 

p o l a r i z e r t h a t d o e s n o t d a m a g e t h e g l a s s

 

 

W h e n t h e u n i t l i g h t s , s p o t s a p p e a r l i g h t ( w h i t e ) w i t h d i s p l a y

 

P o l a r i z e r D e n t

p a t t e r n s d a r k a n d d o n o t v a r y i n s i z e . P h y s i c a l d a m a g e t o t h e

 

 

p o l a r i z e r t h a t d o e s n o t d a m a g e t h e g l a s s .

 

 

 

 

 

H o r i z o n t a l o r d i a g o n a l l i n e s t h a t a p p e a r g r a y w i t h t h e d i s p l a y

 

R u b b i n g L i n e

p a t t e r n s d a r k a n d m a y h a v e r e s u l t e d f r o m a n “ o u t o f c o n t r o l ”

 

r u b b i n g p r o c e s s o n t h e p o l y i m i d e o r “ w a v e s ” o n t h e B E F s o r

 

 

 

 

p r i s m s h e e t s .

 

N e w t o n R i n g

T h e “ r a i n b o w ” e f f e c t c a u s e d b y n o n - u n i f o r m c e l l t h i c k n e s s .

 

 

 

 

 

W h e n t h e u n i t l i g h t s , v a r i a t i o n / n o n – u n i f o r m i t y

 

M o t t l i n g

( s p l o t c h i n e s s ) a p p e a r s l i g h t ( w h i t e ) w i t h t h e d i s p l a y a n d

 

 

m i g h t v a r y i n s i z e .

 

D i m L i n e

W h e n t h e u n i t l i g h t s , l i n e ( s ) i n t h e m o n i t o r ( v e r t i c a l ) o r m a j o r

 

( h o r i z o n t a l ) a x i s a p p e a r d i m , b u t n o t c o m p l e t e l y o n o r o f f .

 

 

 

C r o s s L i n e s O f f

W h e n t h e u n i t l i g h t s , l i n e s i n b o t h t h e m i n o r a n d m a j o r a x i s

 

d o n o t a p p e a r .

 

 

 

B r i g h t / D a r k D o t

A s u b – p i x e l ( R , G , B d o t ) s t u c k o f f / o n ( e l e c t r i c a l ) .

 

 

 

 

1.4.5.6Smudges, Streaks and Smears

When viewing the panel oriented so as to maximize reflected light , there shall be no visible smudging , streaking, smearing or other nonuniformity from contaminants ,fingerprints,or defects in any of the visible surfaces. This is independent of whether the unit is operating or off .

1.4.5.7Other Defects

Undefined defects that are considered to be rejectable by Lite–On will be reviewed by Lite-On as they become apparent. These panels will be referred to the Lite - On Corporate / Manufacturer Purchasing Agreement for disposition.

1.4.5.8LCD Inspection

Put LCD panel on inspection table and illuminate the panel with a daylight fluorescent lamp located above the panel surface such that the luminance at the LCD panel is between 1000 lux and 1500 lux .Defect limits are given in Table 4 .

Average Diameter smaller of

Acceptable Number

Minimum Separation

(L+W)/2 or L/20+2W

 

 

 

 

 

< 0.1mm

Non countable

N / A

0.1 mm ~ 0.3 mm

10

15 mm

0.31 mm ~ 0.5 mm

10

15 mm

0.51 mm ~ 1.25 mm

5

15 mm

1.26 mm ~ 2.5 mm

3

25.4 mm

2.51 mm ~ 3.75 mm

3

25.4 mm

Greater than 3.75 mm

NONE

Not applicable

Note : Allowable distance between spots of two sizes is the minimum separation

number for the smaller spot. Therefore, if there are two spots, 1.30mm and 0.4mm

in diameter, they must be at least 15mm apart.

Page 8
Image 8
Acer RA19WAANU service manual Defects Inspection Spec