JBOD Configurations
41
JBOD Configurations
There are two JBOD configurations covered in this Instal-
lation Guide:
Dual FC Loop mode (including how to daisy chain enclosures)
Quad Loop (single enclosure with 4 FCAL loops)
Note: The following examples show the Copper/Copper I/O
Module option for illustration purposes. The configuration
procedures are identical for all I/O Module options.

Dual FC Loop

Configuration Note: For dual FC Loop enclosures there must be two LS
modules installed in the enclosure.
This section describes the procedure for connecting a dual
FC Loop configuration to your host computer, and how to
daisy chain these enclosures together.

To connect the dual FC Loop enclosure to the host:

Note: You will need two HBA’s in your host system, or a single
HBA with support for two connections. A hub, switch or two hosts
with HBA may also be used.
1Insert the connector on the first cable, into the top connector on
the first I/O module (see Figure 3-2).
2Insert the other end of this cable into the connector on your
HBA.
3Insert the connector on the second cable, into the top connector
on the second I/O module (see Figure 3-2).
4Insert the other end of this cable into the connector on your
HBA.