Installation and Connection

DRS5116

 

 

9.1.Connecting and Configuring Sensor

9.1.1.Specification

In order to run sensor input of DRS series normally, the following conditions are required:

 

Input Ch.

16Ch. Photo coupler inputs *Model Dependant*

 

 

 

Spec.

Input type

N.C. (Normal Close) / N.O. (Normal Open) type

 

 

Supported sensor

Dry contact

 

 

 

 

 

Connecting

Connecting the trimmed wire to terminal block

 

 

 

 

Available input pulse

Min. 500ms

Performance

range

 

 

 

 

 

Output current

Typical DC 12mA

 

 

 

9.1.2. Connecting Sensor Input

Connect S1 ~ S16 (Model Dependant) referring to the following. It shows a dry contact connection. When connecting a non-dry contact type of sensor (e.g. Open collector output) please

contact Wren Technical Support team.

* DRS 5016/5116 Series Shown *

Wren

2003. 09. 06 (v 1.0)

34