Installation and Connection

DRS5116

 

 

9.2.Connecting & Configuring Relay Out

9.2.1.Specifications

In order to operate the relay outputs of the DRS Digital Recording Solution (all models) normally, the following conditions are required.

 

Output Ch.

4Ch. Relay differential outputs

 

 

 

Spec.

Output type

Dry Contact

 

 

 

 

Connecting type

Connect the trimmed wire to the screwless terminal block

 

 

 

 

DC

24V DC, 1.25A, 30W

Rating

 

 

 

125V DC, 0.24A, 30W

 

 

 

 

AC

125V AC, 0.5A, 62.5VA

 

 

 

9.2.2. Connecting Relay Out

When connecting R1 ~ R4 refer to the following diagram. This diagram shows connection to a warning light.

Wren

2003. 09. 06 (v 1.0)

38

Page 38
Image 38
Wren Associates DRS5016, DRS5004, DRS5116, DRS5008 Connecting & Configuring Relay Out, Specifications, Connecting Relay Out