REF |
|
|
|
| USER INTERFACE | DEVICE | FUNCTIONAL | |||
NO |
|
|
|
|
|
|
| DESIGNATION | DESCRIPTION | |
|
|
|
|
|
|
|
| |||
7 | PORT 1/PORT 2 | Indicates if the reverse/forward path optical sig- | ||||||||
|
|
|
|
|
|
|
|
| (green/red) | nals from the STM/HU are normal (green), if no |
|
|
|
|
|
|
|
|
|
| signals are detected (red), or if excessive errors |
|
|
|
|
|
|
|
|
|
| are detected (red). See Note. |
|
|
|
|
|
|
|
|
|
|
|
8 | PORT 3 | Indicates if the diversity reverse path optical signal | ||||||||
| (diversity unit only) | (green/yellow) | from the RU is normal (green), if no signal is | |||||||
|
|
|
|
|
|
|
|
|
| detected (yellow), or if excessive errors are |
|
|
|
|
|
|
|
|
|
| detected (yellow). See Note. |
|
|
|
|
|
|
|
|
|
|
|
9 | SERVICE | Connection point for the | ||||||||
|
|
|
|
|
|
|
|
| (female) | face cable. |
|
|
|
|
|
|
|
|
|
|
|
10 | NET IN | Connection point for the CAN interface input | ||||||||
|
|
|
|
|
|
|
|
|
| cable. |
|
|
|
|
|
|
|
|
|
|
|
11 | NET OUT | Connection point for the CAN interface output | ||||||||
|
|
|
|
|
|
|
|
|
| cable. |
|
|
|
|
|
|
|
|
|
|
|
12 | REV RF OUT | Output connection point for the primary reverse | ||||||||
|
|
|
|
|
|
|
|
| coaxial connector | path RF coaxial cable. |
|
|
|
|
|
|
|
|
|
|
|
13 | REV DIV RF OUT | Output connection point for the diversity reverse | ||||||||
|
|
|
|
|
|
|
|
| coaxial connector | path RF coaxial cable. |
|
|
|
|
|
|
|
|
|
|
|
14 | FWD RF IN | Input connection point for the forward path RF | ||||||||
|
|
|
|
|
|
|
|
| coaxial connector | coaxial cable. |
|
|
|
|
|
|
|
|
|
|
|
15 | POWER | Connection point for the DC power wiring. | ||||||||
|
|
|
|
|
|
|
|
| strip |
|
|
|
|
|
|
|
|
|
|
|
|
16 | No designation | Cover plate | Covers the mounting slot for the wavelength divi- | |||||||
|
|
|
|
|
|
|
|
|
| sion multiplexer module. |
|
|
|
|
|
|
|
|
|
|
|
17 | ALARM OUTPUT | Connection point for an external alarm system. | ||||||||
|
|
|
|
|
|
|
|
| connector | Includes normally open (NO), normally closed |
|
|
|
|
|
|
|
|
| AWG) | (NC), and common (COM) wiring connections. |
|
|
|
|
|
|
|
|
|
|
|
18 | PORT 1 | SC connector | Output connection point for the forward path | |||||||
|
|
|
|
|
|
|
|
| optical fiber. | |
|
|
|
|
|
|
|
|
|
|
|
19 | PORT 2 | SC connector | Input connection point for the reverse path pri- | |||||||
|
|
|
|
|
|
|
|
| mary optical fiber. | |
|
|
|
|
|
|
|
|
|
|
|
20 | PORT 3 | SC connector | Input connection point for the reverse path diver- | |||||||
| (diversity unit only) | sity optical fiber. | ||||||||
|
|
|
|
|
|
|
|
|
|
|
21 |
|
|
|
|
|
|
|
| Chassis ground stud | Connection point for a chassis grounding wire. |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: A more detailed description of LED operation is provided in the applicable System Operation and Maintenance Manual.
Page 4
© 2004, ADC Telecommunications, Inc.