ADCP-75-169 • Issue 1 • June 2004

4 INSTALLATION PROCEDURES

This section provides the installation procedures for the HU and the WDM host module (accessory item). The installation procedures for the Interface Panels are provided in the Digivance Long Range Coverage Solution SMR Interface Panels User Manual (ADCP-75-143). The installation procedures for the CWDM Host Module and the Host Module Mounting Shelf are provided in the Digivance System Coarse Wavelength Division Multiplexer User Manual (ADCP-75-142). Installation of the RU components may proceed separately from installation of the HU.

4.1Before Starting Installation

Before beginning the installation, review the system design plan with the system engineer. Make sure each equipment installation site is identified and located and all cable runs are mapped out. Also identify all tools and materials that are required to complete the installation.

4.1.1Tools and Materials

The following tools are required to complete the procedures in this section:

Box cutter

Pencil or scribe

Medium size flat-bladed screwdriver

Phillips screwdriver (#2)

TORX screwdriver (T20 bit)

Pliers

Wire cutters

Wire stripper

Tool kit for attaching N-type male connectors to coaxial cable

Multimeter

Optical power meter

The following materials are required to complete the procedures in this section:

#18 AWG (1.0 mm) insulated stranded copper wire (for chassis grounding wire)

#18 AWG (1.0 mm) red and black insulated copper wire (for DC power wires)

Category 3 or 5 cable (for external alarm system wires)

#6 ring terminal (1) for #18 wire (for chassis ground wire connection)

#6 fork terminals (2) for #18 wire (for DC power wiring connection)

Single-mode patch cord(s) with SC connectors (1, 2 or 3 depending on the application)

High performance, flexible, low-loss 50-ohm coaxial cable

N-type male connectors

Wire ties

Page 8

© 2004, ADC Telecommunications, Inc.