2.Electrical Service Specifications a. Gas and Steam Models Only

GAS AND STEAM

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC AND 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.

B.Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.

SERVICE

PHASE

WIRE

APPROX.

MINIMUM

FUSING

CIRCUIT

AMP DRAW

 

Dual Element

VOLTAGE

SERVICE

WIRE SIZE

BREAKER

 

 

 

60 Hz

50 Hz

 

Time Delay

 

208

3

28.3

*

50

50

230

3

31.9

*

50

50

240

3

26.7

*

45

45

380

3

16.2

*

25

25

380

4**

16.1

*

25

25

400

4**

16.1

*

25

25

416

4**

16.0

*

25

25

440

3

14.4

*

20

20

460

3

13.9

*

20

20

480

3

13.9

*

20

20

575

3

11.4

*

20

20

* AWG Stranded Wire Type...size wire as per National Electrical Code or local codes.

 

1/23/09

**3-Wire is available.

b.Electric Models Only

ELECTRIC (126 kW)

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC AND 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.

B.Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.

SERVICE

PHASE

WIRE

APPROX.

MINIMUM

FUSING

CIRCUIT

AMP DRAW

 

Dual Element

VOLTAGE

SERVICE

WIRE SIZE

BREAKER

 

 

 

60 Hz

50 Hz

 

Time Delay

 

416

4**

191

*

300

300

460

3

172

*

225

225

* AWG Stranded Wire Type...size wire as per National Electrical Code or local codes.

 

1/23/09

** 3-Wire is available.

 

 

 

 

 

 

22

Page 26
Image 26
ADC AD-170SE installation manual GAS and Steam