150-409-115-05, Issue 5

Functional Description

 

 

The capacities listed for the indoor enclosures in Table 5 assume no solar load. The capacities listed for the outdoor enclosures in Table 6 assume a full solar load as described above. The “Recommended Slot Assignment for Maximum Capacity” column assigns slots according to the following thermal stress reduction rules:

1Always leave at least one empty slot between adjacent doublers. The adjacency rule only applies to the left- and right-hand sides of the doubler. The top of one unit can be adjacent to the bottom of another, though the latter configuration should be avoided if possible.

Rule 1 does not apply to the HRE-458 and HRE-819 enclosures since these products have the required slot separations already built into their design.

2Allow as much room as possible between doublers on all four sides.

Slot assignments that do not follow the recommended configurations in Table 5 and Table 6 are permissible as long as the above two rules are applied. Otherwise, damage may occur to doubler units.

Table 5. Indoor Enclosure Capacities

Vendor

Description

Model #

EDU-409 List

239 T1

1 Doubler

Repeater

 

 

 

Capacity

Capacity

 

 

 

 

 

CHARLES

Indoor wall mount

CiAC2300

7

7

 

 

CiAC2002

2

2

 

 

 

 

 

SPC

Indoor rack and wall

4400-09

18

18

 

mount

 

 

 

 

 

 

 

 

EDU-409 List 1

January 26, 2000

13