Functional Description | |
|
|
The capacities listed for the indoor enclosures in Table 5 assume no solar load. The capacities listed for the outdoor enclosures in Table 6 assume a full solar load as described above. The “Recommended Slot Assignment for Maximum Capacity” column assigns slots according to the following thermal stress reduction rules:
1Always leave at least one empty slot between adjacent doublers. The adjacency rule only applies to the left- and
Rule 1 does not apply to the
2Allow as much room as possible between doublers on all four sides.
Slot assignments that do not follow the recommended configurations in Table 5 and Table 6 are permissible as long as the above two rules are applied. Otherwise, damage may occur to doubler units.
Table 5. Indoor Enclosure Capacities
Vendor | Description | Model # | 239 T1 | |
1 Doubler | Repeater | |||
|
|
| Capacity | Capacity |
|
|
|
|
|
CHARLES | Indoor wall mount | CiAC2300 | 7 | 7 |
|
| CiAC2002 | 2 | 2 |
|
|
|
|
|
SPC | Indoor rack and wall | 18 | 18 | |
| mount |
|
|
|
|
|
|
|
|
January 26, 2000 | 13 |