Functional Description

150-409-115-05, Issue 5

 

 

MICRO DOUBLER CAPACITY DEPLOYMENT RULES

The deployment rules for micro doubler capacity are summarized below:

1Use Table 5 on page 13 for indoor enclosures.

2Use Table 6 on page 14 for outdoor enclosures with Full Solar Load for ambient temperatures up to 46.1 °C maximum.

3The capacities shown in Table 6 can be increased by two for non-solar load (shaded or manhole applications).

4Decrease capacities in Table 6 by one for every 2.7 °C increase, or fraction thereof, in ambient temperatures above 46.1 °C.

5Increase the capacities by one for every full +2.7 °C reduction in ambient temperature below 46.1 °C.

6Decrease any outdoor capacity by one for every four E1 repeaters, or fraction thereof, that are installed with the doublers.

7For all outdoor applications, decrease the capacity by one for every two adjacent doublers that are not separated by at least one empty slot.

18

January 26, 2000

EDU-409 List 1