Overview

LTPH-UM-1237-04

 

 

OPERATIONAL CAPABILITIES

Application

With two HMU-319 management units installed, the HRM-238 shelf provides network management for up to 56 HiGain line units.

Recommended Network Setup for 220 Type Shelves

The configuration shown in Figure 2 is the recommended setup for 220 type mechanics shelves. Position the HRM-238 shelf between the 220 type shelves, with up to two 220-type shelves above and two below. This limits the distance for the wire leads between the connectors for the management units and the line units they manage. Figure 2 shows the HRM-238 shelf from the rear view with the A-side connectors on the right and the B-side connectors on the left. The leads from the HRM-238 shelf connector attach to the Network Management Agent (NMA) pins on the rear of the 220-type mechanics shelves for each line unit managed. The NMA pin on 220 type chassis is pin 46.

NMA 1 to 14 B

NMA 15 to 28 B

NMA 1 to 28 B

 

HCS-417/418

-48V A

 

 

-48V B

 

 

 

 

 

HCS-417/418

-48V A

 

 

-48V B

 

 

 

 

CO -48V

 

 

Supply

 

 

 

 

TB1

 

 

Network B

HRM-238

Network A

NMA 1 to 28 A

-48V A

HCS-417/418NMA 1 to 14 A

-48V B

-48V A

HCS-417/418NMA 15 to 28 A

-48V B

H0544-B

Figure 2. Recommended Network Setup for 220 Type Shelves

2

July 21, 2004

HRM-238 List 1

Page 10
Image 10
ADC HRM-238 L1 user manual Operational Capabilities, Application