Adder Technology ADD0038/1 Appendix A. Cable and connector specifications, Important Note, Page

Models: ADD0038/1

1 66
Download 66 pages 51.07 Kb
Page 60
Image 60
Appendix A. Cable and connector specifications

Appendix A. Cable and connector specifications

IMPORTANT NOTE

The maximum cable lengths supported vary widely between devices and cables. It may be possible to use cables that are longer than those specified below with certain PCs and peripherals but this cannot be guaranteed. If you experience problems try using shorter cables.

A1. Keyboard, monitor and mouse to SmartView XPro

Cable specification:

All of the shared devices plug directly into the relevant ports at the rear of the SmartView. If you use an AT style keyboard you will need an AT (5 pin DIN female) to PS/2 (6 pin mini-DIN male) converter. Keyboard, monitor and mouse extension cables can be used to increase the distance from SmartView up to 10m. Most keyboards and mice will also operate at distances of 20 metres.

A2. AdderLink to SmartView XPro

Cable specification:

The AdderLink uses standard 4-pair unshielded twisted pair cable of the same type that is commonly used for Ethernet and other networks. Unshielded and shielded types may be used at distances up to 200 metres.

IMPORTANT WARNING

Do not connect the SmartView's extender ports to an Ethernet hub or other digital network device. The signals carried on the twisted pair cable between the SmartView and the AdderLink are ANALOGUE. Plugging the SmartView or AdderLink into a digital network device such as a hub may damage you devices

SmartView XPro

Installation and Use

Page 60

Page 60
Image 60
Adder Technology ADD0038/1 Appendix A. Cable and connector specifications, Important Note, A2. AdderLink to SmartView XPro