15
3. Connect.the.other.end.of.the.cascade.
link.cable.to.the.remote.user.port.
(RJ45.socket).on.the.front.panel.of.
the.AdderView.CATx.1000.unit..
4. Repeat.steps.2.and.3.for.the.cascade.
links.between.the.AdderView.
CATxIP.1000.and.each.AdderView.
CATx.1000.unit.
Connecting units in cascade
The.method.for.cascading.AdderView.CATxIP.1000.and.AdderView.CATx.
1000.units.is.straightforward.and.requires.no.hardware.settings.or.lengthy.
configuration.process..
The.method.of.linking.units.is.the.same.regardless.of.the.cascade.level,.or.
number.of.devices.attached..Put.simply:.
• A single cascade link is made by connecting a computer connections
socket of the ADDerVieW cAtxip 1000 unit to the remote user port
socket of the ADDerVieW cAtx 1000 unit below it.
Please.consider.the.following.when.making.cascade.connections.between.units.
Tips for successful cascading
•. The.maximum.number.of.levels.for.a.cascade.is.two.
•. For.each.cascade.link,.use.a.standard.category.5,.5e.or.6.twisted-pair.cable,.
terminated.at.each.end.with.an.RJ45.connector..There.must.be.no.crossover.
connections.within.the.cable..The.cascade.link.cables.can.be.up.to.50m.(160.
feet).in.length..Also.ensure.that.the.total.length.from.the.top.AdderView.
CATx.1000.to.any.CAM.does.not.exceed.10m.
•. The.procedure.given.opposite.may.be.carried.out.in.any.order.but.for.
clarity.the.instruction.will.begin.at.the.AdderView.CATxIP.1000.unit..The.
procedure.remains.the.same.regardless.of.exactly.which.cascade.levels.are.
being.connected..The.basic.rule.is.that.each.link.is.made.by.connecting.a.
COMPUTER CONNECTIONS.port.of.the.ADDERVIEW CATxip 1000 (upper.switch).to.
the.REMOTE USER PORT.(on.the.front.panel).of.the.ADDERVIEW CATx 1000.
See also
•. Addressing computers in a cascade
To connect units in cascade
1. Ensure.that.power.is.disconnected.from.the.
AdderView.CATxIP.1000.and.all.other.units.
to.be.connected....
2. Connect.one.end.of.the.cascade.link.cable.
to.an.appropriate.COMPUTER CONNECTIONS.
port.on.the.rear.panel.of.the.AdderView.
CATxIP.1000.
INDOORUSE ONL
Y
3 2 1
765
COMPUTERCONNECTIONS
KVM
only
Once.the.units.and.computers.have.been.connected,.you.can.edit.their.names.
to.make.it.much.easier.to.locate.them..See.the.To create a new host entry.
section.in.the.‘Host.configuration’.page.of.Appendix.2.for.more.details.