Remote switching control

The port switching functions of the AdderView CATxIP

REMOTE

1000 units can be remotely controlled by an RS232 link to

CONTROL

the OPTIONS port on the rear panel.

 

The sending device must use the following RS232

 

communication settings:

 

Baud rate:

19200 bps.

 

Data bits:

8.

 

Parity:

None.

 

Stop bits:

1

 

No handshaking is implemented, however, valid command characters will be echoed back to the sending device.

Note: You must ensure that the AdderView CATxIP 1000 unit has it Options serial ports set to ‘Sync Units’. This setting (together with the baud rate selection) can be made either via the local or global user configuration menus.

The value of the byte received via the serial link determines which computer port should be linked through to the user port. The table given here summarises the valid control codes:

Cable from serial

control device

 

 

AdderView CATxIP 1000

 

 

rear panel

 

 

OPTIONS

5V

 

 

2.

A

16

0

 

12

 

 

 

 

 

 

 

Host computer port/channel

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

0 (video off)

10

11

12

13

14

15

16

17

18

19

1A

1B

1C

1D

1E

1F

71

 



18