Local and remote user access
Local users (directly connected) and remote users (via an Adder X100/X200 extender) gain access to the AdderView CATx unit in exactly the same way. Global users, linking via a special viewer, are handled in a different manner.
To gain access as a local or remote user:
1 From a local or remote keyboard, press any key to display the login prompt:
| ADDERVIEW CATx IP | Enter your Login | |||
| User Name: |
|
|
| name here |
| Password: |
|
|
|
|
| Port 1 login |
|
|
|
|
If the above login prompt is not displayed, you are either already logged in to the AdderView CATx unit, or the security features have not been implemented. In such cases see ‘To view this menu at any time’ below.
2Enter your username and password. Providing you have the correct permissions, the screen will display the main menu, showing you a list of computers for which you have permission to access:
Selecting a computer
There are four main ways for local and remote users to select a specific computer channel:
•Using the front panel controls (discussed below) – this is a straightforward method, if the AdderView CATx is nearby.
•Using hotkeys – this is a good method if you continually access a small number of computers.
•Using the
•Using mouse buttons – this is a good method for cycling between a small number of computers.
For all methods (if the confirmation box option is enabled), when the required port is selected, a pop up message will be displayed to confirm the computer name or number, and its status. Alternatively, an error message explaining why a connection is not possible (press to cancel the latter type of message).
To avoid the ‘hall of mirrors’ effect
Default names for each computer port
Identification of your user port
Your Login name
ADDERVIEW CATx IP
Computer | Port | ||
Computer 1 | 01 |
| |
Computer 2 | 02 |
| |
Computer 3 | 03 |
| |
Computer 4 | 04 |
| |
Computer 5 | 05 |
| |
Computer 6 | 06 |
| |
Computer 7 | 07 |
| |
Computer 8 | 08 |
| |
User port 1 | Status | ||
ADMIN |
| SHARED USE | |
| |||
These indicators show which systems are currently accessible (green) or inaccessible (red).
This column shows the AdderView CATx address for each computer. If you wanted to select ports using the hotkey method, these are addresses that you would enter.
Link status of your user port
IMPORTANT: Never configure a system so that your viewer is viewing itself.
When controlling a host computer via the local user port or a remote user port, if the host computer is networked it is possible to make the VNC viewer or a browser to create a link back to itself via the global (IP) capabilities of the unit. This will set up a ‘hall of mirrors’ effect, where the computer is viewing itself . into infinity.
While technically possible, the AdderView CATx IP unit is not designed to withstand this treatment and could sustain damage.
To select a computer using the front panel controls
Note: It is possible for the front panel controls to be limited to selecting only the on screen menu or a blank screen. If this is the case please use a different switching method or contact your system administrator for details.
To view this menu at any time: Press and hold the hotkeys (usually and ), then press and finally release all three keys.
Note: The and keys when pressed in combination are called ‘hotkeys’ and they signal to the AdderView CATx that you wish to control it, rather than the host computer. However, if these particular hotkeys clash with another device or program, then your administrator may change them to a different
combination. If the combination fails to work, then please contact your system administrator for details.
1Press the USER button until the adjacent numeric indicator displays the port number to which you are connected.
2Press the COMPUTER button until the adjacent numeric indicator shows the required computer channel number.
Note: If security has been enabled then only computer channels to which the current user port has permission will be displayed.
As well as the 16 (or 24) standard computer ports, there are also two additional special ports that appear after the last port, either 16 or 24:
This port provides no video signal so that a connected power saving monitor will be prompted to enter into its power saving mode.
This port connects the current user port to the
51