ADIC DS9000 Series manual Data Protection, Right Indicator Panel, State Meaning Tape in Use

Models: DS9000 Series

1 60
Download 60 pages 46.01 Kb
Page 39
Image 39

Data Protection

Write-Protection of the Data Cartridge While Inside the Drive

The Write-Protectswitch on the data cartridge can be moved while the cartridge is loaded into the drive. The drive will turn on the Write Protected LED immediately. However, if the drive is writing to the tape, write protect does not take effect until the write operation is completed.

If you move the Write-Protectswitch from the write-protected position (on the left) to the write-enabled position (to the right), the tape becomes

Swrite-enabled after several seconds.

If you move the Write-Protectswitch from the write-enabled position (on the right) to the write-protected position (to the left), the tape becomes write-protected after several seconds.

Write-Protection of the Data Cartridge Outside of the Drive

Move the Write-Protectswitch to the left to write-protect the tape. The Write Protect LED (orange) is ON and data cannot be written to, or erased from the tape.

Move the Write-Protectswitch to the right to make the tape write-enabled. Data can now be written to, or erased from the tape, assuming it is not already software write-protected.

Tape in Use

Whenever the Tape in Use LED (yellow) is ON steady, the tape is ready to use. When the tape is being read, written, or rewound, the Tape in Use LED blinks.

Use the following table to determine what is happening during cartridge use:

 

 

(Right Indicator Panel)

 

 

 

 

 

 

 

LED

State

Meaning

 

 

 

 

 

 

 

Tape in Use

ON steady

A cartridge is loaded, but the tape is not moving. This

 

 

 

 

can mean no application is communicating with the

 

 

 

 

controller, or that the application is communicating but is

 

 

 

 

not delivering commands for tape motion.

 

 

 

Blinks irregularly

A read or write is in progress.

 

 

 

Blinks regularly

Tape is loading, unloading, or rewinding.

 

 

 

 

 

 

 

Operate Handle

ON and beeper sounds

Tape is unloaded into the cartridge and the cartridge can

 

 

 

 

now be removed, or if the drive is unloaded, a cartridge

 

 

 

 

can now be inserted.

 

 

 

 

 

 

 

All LEDs

Blinking

An error has occurred during operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation and Maintenance

27

Page 39