ADIC DS9000 Series manual Front Panel Indicators and Controls, Display Beeper

Models: DS9000 Series

1 60
Download 60 pages 46.01 Kb
Page 18
Image 18

 

Front Panel Indicators and Controls

 

 

2-line by 20-character LCD

Displays drive status, error messages, POST results

Display

 

 

 

Beeper

Sounds whenever it is OK to operate the cartridge insert/release handle. The green

 

Operate Handle LED should be ON whenever the Beeper sounds.

 

 

Write Protected

ON = Tape write-protected.

(orange)

OFF = Tape write enabled.

 

 

Tape in Use

Blinking = Tape moving.

(yellow)

ON = Tape loaded; ready for use.

 

 

Use Cleaning Tape (yellow)

ON = Drive head needs cleaning, or the tape is bad.

 

OFF = cleaning complete, or cleaning unnecessary.

 

 

Operate Handle

ON = OK to operate the cartridge insert/release handle.

(green)

OFF = Do not operate the cartridge insert/release handle.

 

 

Density Select 2.6

ON = Tape is recorded in 2.6 GB format.

(yellow)

Blinking = Tape is recorded in another density.

 

 

Density Select 6.0 (yellow)

ON = Tape is recorded in 6.0 GB format.

 

Blinking = Tape is recorded in another density.

 

 

Density Select 10.0

ON = Tape is recorded in 10.0 GB format.

(yellow)

Blinking = Tape is recorded in another density.

 

 

Density Select 15.0

ON = Tape is recorded in 15.0 GB format.

(yellow)

Blinking = Tape is recorded in another density.

 

 

Density Select 20.0

ON = Tape is recorded in 20.0 GB format.

(yellow) [DS9400D/L, ADIC

Blinking = Tape is recorded in another density.

4000]

 

 

 

Density Select 35.0

ON = Tape is recorded in 35.0 GB format.

(yellow) [DS9700D]

Blinking = Tape is recorded in another density

 

 

Density Select 40.0

ON = Tape is recorded in 40.0 GB format.

(yellow) [DS9800D]

Blinking = Tape is recorded in another density

 

 

Compress

ON = Compression mode enabled.

(yellow)

OFF = Compression mode disabled.

 

 

Density Override (yellow)

ON = Density selected from front panel.

 

OFF (default) = Density selected from host.

 

Blinking = In density selection mode.

 

 

Unload Button

Pressing this button initiates a manual unload of the tape. This may take from 10

 

seconds to 4 minutes depending on tape position.

 

 

Cartridge Insert/Release

Lift this handle (only when the Operate Handle LED is ON, and after the

Handle

momentary beep sounds) to load or eject a cartridge from the drive. The handle lifts

 

to the open position and lowers to the closed position.

 

 

6