Drive Status

Drive Status

After completion of the drive POST and initialization, each drive will be in one of the four states listed in the following table:

Drive State

Indicator Displays and Actions

 

 

 

1.

No cartridge is present

A. The Tape in Use LED turns OFF.

 

 

B. The Operate Handle LED turns ON.

 

 

C. The handle is unlatched.

 

 

D. The drive beeps momentarily.

 

 

2. A cartridge is present and the handle

The drive loads the cartridge. When the Tape in Use LED stops

 

is closed.

blinking and stays ON, the tape’s actual density lights. For

 

 

example, if the actual tape density is 2.6, then the LED turns ON

 

 

next to the 2.6 label. When the Density Override LED blinks,

 

 

you can select a density. The drive is ready for use.

 

 

3. A cartridge is present, but the handle

The Tape in Use LED turns OFF. The Operate Handle LED

 

is open.

flashes. The Scalar Library will close the handle and the drive will

 

 

load the cartridge. When the Tape in Use LED stops blinking and

 

 

stays ON, the tape’s actual density lights. For example, if the actual

 

 

tape density is 2.6, then the LED turns ON next to the 2.6 label.

 

 

When the Density Override LED blinks, you can select a density.

 

 

The drive is ready for use.

 

 

 

4.

The drive detects an error condition.

Then all right or left side LEDs blink repeatedly. You may try to

 

 

unload the tape and reinitialize the drive by pressing the Unload

 

 

key or turn power OFF and then ON again. The right or left side

 

 

LEDs stop blinking and the drive tries to reinitialize. The LEDs

 

 

turn ON steadily again and then turn OFF if the test succeeds.

 

 

 

The drive POST completes in about 13 seconds on each drive, and the drives will respond normally to all commands. However, it may take longer for the media to become ready.