Using the Mailbox (Scalar 458 only)

Using the Mailbox (Scalar 458 only)

On-Line Mode

When the Scalar Library is in On-Line Mode the application software is in control and directs all library operations. The application software can use the Mailbox to insert or remove individual cartridges to/from the drives, or to/from the cartridge storage shelves. Follow closely the instructions the application software provides on your host computer system monitor.

The design of the Mailbox includes access control doors and cartridge stops in each of the media slots. The doors are unlocked, except when the library is performing a media transport operation (pick and place). The cartridge stops are solenoid controlled and prevent incorrect insertion of the media. The stops are held in the raised position whenever the Mailbox access doors are unlocked. During library pick and place operations the stops are lowered, allowing the library to insert or remove cartridges from the slots using the Media Picker.

Warning

The Mailbox access control doors are locked when the application software performs a media transport operation (pick and place), or, the application can lock the access control doors at any time. You cannot open either door during this operation without severely damaging the Scalar 458. Wait until your application software instructs you to open either of these doors.

Loading a Cartridge into Scalar 458 Library

Open the appropriate Mailbox access control door as instructed.

Place the cartridge into the appropriate slot of the Mailbox with the write-protect switch at the top and the barcode label facing you. Slide the cartridge in until the stop will not allow it to go any farther.

Note

The cartridge is inserted with the write-protect switch at the top and the barcode label facing you. However, the cartridge stops will prevent you from installing the media incorrectly.

Close the Mailbox access control door.

Follow any additional instructions provided by the application software.

The application software will now perform the intended operation with the cartridge.

Unloading a Cartridge from Scalar 458 Library

The application software will cause the cartridge to be ejected from the drive and will issue the pick and place commands to have the library move the cartridge to a Mailbox slot.

Open the appropriate access control door and remove the cartridge from the Mailbox.

Close the access control door.