ADIC Scalar Series manual Map Slots, Calibrate X and Y, Test Secondary Fan, Diagnostics Menu

Models: Scalar Series

1 84
Download 84 pages 29.72 Kb
Page 69
Image 69
Map Slots

Use LEFT or RIGHT to select the desired field. Select the drive row and drive using UP or DOWN. Press ENTER to activate.

rr

=

Row number (01 - 2)

dd

=

Drive number (01 - 04)

This function is usually used for diagnostics only by a trained technician.

Map Slots

The Map Slots function will cause the Scalar Library to update its cartridge inventory log. Selecting “N” in the Scan Barcodes field will prevent the library from updating its barcodes inventory log. If the Barcode Scanner configuration parameter is set to “N”, the setting of the Scan Barcodes field is ignored.

Use LEFT or RIGHT to select the Scan Barcodes field. Use UP or DOWN to select Y or N. Press ENTER to activate.

This function is usually used for diagnostics only by a trained technician.

Calibrate X and Y

The Calibrate X and Y function will cause the Scalar Library to move the Media Picker to the home position (x = left, y = bottom) and update its home position constant.

Press ENTER to activate.

This function is usually used for diagnostics only by a trained technician.

Test Secondary Fan

The Test Secondary Fan function will cause the Scalar Library to turn the secondary cooling fan on or off. Exiting this function via either the ESC or MENU key will turn off the secondary fan, unless the thermal IC on the Main Controller board reads 45º C or more.

Diagnostics Menu

59

Page 69
Image 69
ADIC Scalar Series manual Map Slots, Calibrate X and Y, Test Secondary Fan, Diagnostics Menu