ADTRAN 1200350L1 user manual PPP/Max Config, PPP/Max Timer, PPP/Max Failure, PPP Profile/Filters

Models: 1200350L1

1 134
Download 134 pages 2.52 Kb
Page 77
Image 77
PPP/Max Config

Chapter 4: Configuration Overview

PPP/Max Config

Write security: 3; Read security: 5

This value is the number of unanswered configuration requests that should be transmitted before giving up on a call.

Possible values: 5, 10 (def), 15, 20.

PPP/Max Timer

Write security: 3; Read security: 5

This value is the number of seconds to wait between unanswered configuration requests.

Possible values: 1 sec, 2 secs (def), 3 secs, 5 secs, 10 secs.

PPP/Max Failure

Write security: 3; Read security: 5

Due to the nature of PPP, configuration options may not be agreed upon between two PPP peers. This value is the number of configu- ration requests that should occur before an option is configuration- rejected. This allows a connection to succeed that might otherwise fail.

Possible values: 5 (def), 10, 15, 20.

PPP Profile/Filters

The Router Option Module can block packets in and out of a WAN port by use of the filters. They are set up in two steps:

1.Define the types of packets that would be of interest in the Con- figuration/Security/Filter Defines menu,

2.Set up the filter type and combination of defines that will cause a packet block.

Filters/WAN-to-LAN (In) Write security: 2; Read security: 5

The packets which come into the Router Option Module can be fil- tered in three ways:

Disabled (def)

Turns off packet input filtering. No incoming

 

packets are blocked.

Block All

All incoming packets from the WAN are

 

blocked except as defined in the Filters/In

 

Exceptions list.

61200350L1-1

Router Option Module User Manual

4-41

Page 77
Image 77