Section 3 Engineering Guidelines

TRACER 4106/4206 System Manual

 

 

 

 

 

Table 1. Rear Panel Description1

 

Name

Connector

Description

 

 

 

 

A

RS-232

DB-25 (female)

VT100 terminal (or PC with terminal emulation software)

 

 

 

connection

B

Test

1/4” bantam

Factory test connection

C

T1A - T1D

RJ-48C

T1 device connection

D

Alarm

Terminal block

External alarm monitoring system connection

E

DC Power

Terminal block

21-60 VDC power source connection

F

Fuse

N/A

2 A, 250 V, 2 inch slow-blo fuse

G

Antenna

N-Type

Antenna feedline cable connection

H

Ground Lug

N/A

Earth ground connection

1 Detailed discussions (including pinouts) of rear panel components (where applicable) follow the table.

RS-232 Connection (DB-25) — Terminal Use

The RS-232connector provides a female DB-25 terminal connection (wired as a DCE interface), which is used for terminal access to the TRACER 4106/4206 system. The RS-232port provides the following functions:

Accepts EIA-232 input from a PC or terminal for controlling the TRACER 4106/4206 system

Operates at 9600 bps

Table 2 shows the pinout. Wiring diagrams for connecting to the RS-232connector (for various applications) are provided following the pinout.

 

 

Table 2. RS-232 Connection Pinout

 

 

 

 

PIN

NAME

 

DESCRIPTION

 

 

 

 

1, 7

GND

 

Ground

 

 

 

 

2

TX

 

Transmit

 

 

 

 

3

RX

 

Receive

 

 

 

 

4

RTS

 

Request To Send

 

 

 

 

5

CTS

 

Clear To Send

 

 

 

 

6

DSR

 

Data Set Ready (Modem Control Only)

 

 

 

 

8

CD

 

Carrier Detect

 

 

 

 

9-19

 

Unused

 

 

 

 

20

DTR

 

Data Terminal Ready (Modem Control Only)

 

 

 

 

21

 

Unused

 

 

 

 

22

RI

 

Ring Indicator

 

 

 

 

23-25

 

Unused

 

 

 

 

28

© 2004 ADTRAN, Inc.

612804206L2-1A

Page 28
Image 28
ADTRAN 4106 Plan A, 4206 Plan A RS-232 Connection DB-25 Terminal Use, Rear Panel Description, Name Connector Description