Section 5 User Interface Guide

 

 

 

 

 

 

 

Table 1. Receiver Sensitivity for the TRACER 4106/4206

 

 

 

 

 

 

 

 

Delivered

Receiver Sensitivity

 

Active

 

 

Bandwidth

TRACER 4106

TRACER 4206

 

T1 Ports

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4xT1

-93 dBm

-90 dBm

 

A – D

 

 

 

 

 

 

 

 

 

2xT1

-96 dBm

-93 dBm

 

A, B

 

 

 

 

 

 

 

 

 

1xT1

-98 dBm

-95 dBm

 

A

 

 

 

 

 

 

 

 

Both ends of the TRACER link must be set to the same number of active T1 ports. The TRACER 4106/4206 comes factory programmed with ACTIVE T1 PORTS set to 4XT1.

When changing active T1 ports on installed links, change the remote end first. If the local end is changed first, remote configuration capability is lost. In the event the local end is changed first and the link is dropped, reset the local end to the previous setting to restore the link.

>TRACER SYSTEM OPTIONS > MODEM CONTROL

Configures the modem control leads on the RS-232 port (terminal interface located on the rear panel of the unit). Set MODEM CONTROL to ENABLED when connecting the unit to a modem (using a null modem adapter). Setting MODEM CONTROL to DISABLED prevents the TRACER 4106/4206 from monitoring DCD and enables data to be sent to the VT100 continuously. MODEM CONTROL must be set to DISABLED when the VT100 terminal is in use. The TRACER 4106/4206 comes factory programmed with MODEM CONTROL set to

DISABLED.

Press <Ctrl+Z> three times from the terminal interface to disable MODEM CONTROL when the modem control leads are active.

>TRACER SYSTEM OPTIONS > MODEM CONNECTION (LOGOUT)

Causes the TRACER 4106/4206 to de-assert Clear To Send (CTS) and DSR for a time greater than 20 msec. This signals the modem to disconnect the analog connection. Hangup-On-DTR-Drop may need to be explicitly enabled on some modems. If PASSWORD PROTECTION is ENABLED, this menu also causes the unit to close the current session and return to the TRACER System Status menu page and wait for password input.

>TRACER SYSTEM OPTIONS > PASSWORD ENABLE

Configures password protection for the VT100 terminal interface. Password protection for the

TRACER 4106/4206 requires password input from the TRACER 4106/4206 System Status menu page when connecting to the unit. When configured for password protection, the TRACER 4106/4206 closes any terminal session that remains inactive for more than 10 minutes. The TRACER 4106/4206 comes factory programmed with PASSWORD ENABLE set to DISABLED.

>TRACER SYSTEM OPTIONS > PASSWORD

Sets the password for password protection of the TRACER 4106/4206 VT100 terminal interface. Enter up to 8 alphanumeric characters. The system password is case sensitive.

The default password for the TRACER 4106/4206 is tracer.