Chapter 3. Operation

installing modules by simply specifying the module that you want to install in each slot.

TYPE automatically displays the name of an installed module. If you want to change this field to a different type of module, you must set TYPE to EMPTY before selecting the other module.

MENU

Displays additional status and configuration menus for the selected

 

module. (To access the submenus for this item, use the arrow keys to

 

scroll to the MENU column for the module you want to edit, and press

 

Enter.) For detailed information on each submenu item, see the section

 

Modules/Menu on page 31.

ALARM

Read security: 5

 

Displays an alarm condition on the NxT1 HSSI/V.35 Module. Press Enter in

 

this field to activate the menu.

TEST

Read security: 5

 

Displays test name if the NxT1 HSSI/V.35 Module is executing a test. Press

 

Enter in this field to activate the menu.

STATE

Displays module status as either ONLINE of OFFLINE. Even though a module

 

is physically installed, it must be marked as online for it to be considered an

 

available resource. This field allows an installed module to be marked as of-

 

fline, which may be useful in system troubleshooting. If you choose OFFLINE,

 

the module will not be in alarm condition, but will display OFFLINE.

Once a module is installed, STATE must be set to ONLINE in order for the ATLAS 800 Series unit to use the module for any data bandwidth.

STATUS

This read-only field provides status information on the NxT1 HSSI/V.35

 

Module. The following messages may display:

ONLINE

The module is enabled, and is responding to the system controller’s status

 

polls. This is the normal response of the system.

NO RESPONSE

The module is enabled, but is not responding to the system controller’s status

 

polls. This response indicates either a problem in the system or that the mod-

 

ule is not installed.