ADTRAN T200 H2TU-R dimensions B. Circuit Technology Configuration Chart Part

Models: T200 H2TU-R

1 21
Download 21 pages 24.62 Kb
Page 14
Image 14
Table 6B. Circuit Technology Configuration Chart (Part 2)

1 4

Section 61150090L1-5A, Issue 1

61150090L1-5A

Table 6B. Circuit Technology Configuration Chart (Part 2)

 

 

Lead

Cable

Pair

Tip

Ring

HDSL

 

HDSL

ISDN

DDS

ISDN

HDSL

Pack #

 

Binder

#

Wire

Wire

HRE

 

HTU-R

TR-R

TRDDS-R

Bridle-R

FNID

and Pin #

 

Color

 

Color

Color

 

 

 

 

 

 

 

CP8,

5-15

T1-R1

Blue

8

Red

Green

Cust, Loop 1

 

To Cust

NC

To Cust (RX)

Cust

To Cust

 

7-13 T1-R1

Blue

20

Yellow

Slate

Ntwk, Loop 1

Ntwk, Loop 1

NC

NC

Ntwk, Loop 1

Ntwk

 

41-47

T-R

Orange

8

Red

Green

Ntwk, Loop 2

Ntwk, Loop 2

Ntwk

To/Fm Ntwk

Ntwk, Loop 2

NC

 

55-49 T-R

Orange

20

Yellow

Slate

Cust, Loop 2

 

Fm Cust

Cust-NT1

Fm Cust (TX)

NC

Fm Cust

CP9,

5-15

T1-R1

Blue

9

Red

Brown

Cust, Loop 1

 

To Cust

NC

To Cust (RX)

Cust

To Cust

 

7-13 T1-R1

Blue

21

Violet

Blue

Ntwk, Loop 1

Ntwk, Loop 1

NC

NC

Ntwk, Loop 1

Ntwk

 

41-47

T-R

Orange

9

Red

Brown

Ntwk, Loop 2

Ntwk, Loop 2

Ntwk

To/Fm Ntwk

Ntwk, Loop 2

NC

 

55-49 T-R

Orange

21

Violet

Blue

Cust, Loop 2

 

Fm Cust

Cust-NT1

Fm Cust (TX)

NC

Fm Cust

CP10,

5-15

T1-R1

Blue

10

Red

Slate

Cust, Loop 1

 

To Cust

NC

To Cust (RX)

Cust

To Cust

 

7-13 T1-R1

Blue

22

Violet

Orange

Ntwk, Loop 1

Ntwk, Loop 1

NC

NC

Ntwk, Loop 1

Ntwk

 

41-47

T-R

Orange

10

Red

Slate

Ntwk, Loop 2

Ntwk, Loop 2

Ntwk

To/Fm Ntwk

Ntwk, Loop 2

NC

 

55-49 T-R

Orange

22

Violet

Orange

Cust, Loop 2

 

Fm Cust

Cust-NT1

Fm Cust (TX)

NC

Fm Cust

CP11,

5-15

T1-R1

Blue

11

Black

Blue

Cust, Loop 1

 

To Cust

NC

To Cust (RX)

Cust

To Cust

 

7-13 T1-R1

Blue

23

Violet

green

Ntwk, Loop 1

Ntwk, Loop 1

NC

NC

Ntwk, Loop 1

Ntwk

 

41-47

T-R

Orange

11

Black

Blue

Ntwk, Loop 2

Ntwk, Loop 2

Ntwk

To/Fm Ntwk

Ntwk, Loop 2

NC

 

55-49 T-R

Orange

23

Violet

Green

Cust, Loop 2

 

Fm Cust

Cust-NT1

Fm Cust (TX)

NC

Fm Cust

CP12,

5-15

T1-R1

Blue

12

Black

Orange

Cust, Loop 1

 

To Cust

NC

To Cust (RX)

Cust

To Cust

 

7-13 T1-R1

Blue

24

Violet

Brown

Ntwk, Loop 1

Ntwk, Loop 1

NC

NC

Ntwk, Loop 1

Ntwk

 

41-47

T-R

Orange

12

Black

Orange

Ntwk, Loop 2

Ntwk, Loop 2

Ntwk

To/Fm Ntwk

Ntwk, Loop 2

NC

 

55-49

T-R

Orange

24

Violet

Brown

Cust, Loop 2

 

Fm Cust

Cust-NT1

Fm Cust (TX)

NC

Fm Cust

 

 

 

Cable

Pair

Tip

Ring

 

 

 

 

NOTES:

 

 

Function

Lead

Binder

Wire

Wire

 

1.

CP# is the circuit pack number inside the shelf.

 

#

 

 

 

 

 

Color

Color

Color

 

2.

NC = Not Connected.

 

 

 

 

 

 

 

 

 

 

 

 

 

Pos/

 

 

 

 

Cable "A"

3.

Pin 11 of each card edge connector is Ground.

 

Primary Fan

Blue

25

Violet

Slate

4.

Fans must be functional to prevent heat buildup.

 

Neg

Only

 

 

 

 

 

 

 

5.

The CO installed FPU is required to power and monitor fan cooling system.

 

 

 

 

 

 

 

 

Secondary

Pos/

Orange

25

Violet

Slate

Cable "A"

6.

The Fan Powering Unit is purchased separately.

 

7.

Cable "A" connects to the top T400 shelf and both fan boards.

 

Fan

Neg

Only

 

 

 

 

 

8.

Cable "B" connects to the bottom T400 shelf.

 

 

 

 

 

 

 

 

 

 

 

 

 

Blue

SP#1

White

Red

 

9.

The two T400 shelves have 12 slots each.

 

 

Spare Pairs

 

Blue

SP#2

White

Black

 

10. Each shelf has its own surge arrestor board.

 

 

Orange

SP#1

White

Red

 

11. Use Table 8 at the end of this document to record customer information.

 

 

 

 

 

 

 

Orange

SP#2

White

Black

 

 

 

 

 

 

 

Page 14
Image 14
ADTRAN T200 H2TU-R dimensions B. Circuit Technology Configuration Chart Part