MIC-3081 User Manual --- Page 13
2.3.6 Replacing the Hot-swap Fan and Air Filter
The MIC-3081 provides two hot-swap fans underneath the card slots and two
blowers on the top. Each fan/blower can be individually replaced. This can be done
without turning off the system power or interrupting system operation.
Follow these steps to replace a fan:
1. Unfasten the fan's holder.
2. Slide the fan's holder out.
3. Replace the old fan with a new one.
4. Slide the fan's holder in.
5. Fasten the new fan's holder.
The air filter may become dirty after a period of time. Follow these steps to replace
a filter:
1. Remove the filter cover.
2. Replace the dirty filter with a clean one.
3. Reattach the filter cover.
Repeat steps 1 to 3 to replace other filters.