28

9. Specifications

MODELL

Protect PV 2000

Protect PV 2800

DC INPUT

 

 

 

Nominal DC voltage

360 VDC

360 VDC

 

max. PV open voltage

500 VDC

500 VDC

 

MPPT range

150–450 VDC

150–450 VDC

 

Working range

100–500 VDC

100–500 VDC

Number of MPP Tracker

1

1

 

max. Input current

10 ADC

13 ADC

aC OUTPUT

 

 

 

Output power

2000 W

2800 W

 

max. power

2200 W

3000 W

 

Operational voltage

184–264,5 VAC

184–264,5 VAC

 

Operational frequency

50 Hz

50 Hz

Current distorsion

< 3 %

< 3 %

 

Power factor (cos ϕ)

~ 1

~ 1

 

system

 

 

 

Display

LCD Display

LCD Display

1 line, 16 Char.

1 line, 16 Char.

 

Max. efficiency

> 96 %

> 96 %

 

Euro efficiency

> 95 %

> 95 %

 

Protection degree

IP 43

IP 43

 

Operation temp.

–20 °C ~ 55 °C

–20 °C ~ 55 °C

Humidity

0 ~ 95 %

0 ~ 95 %

 

non-condensing

non-condensing

 

 

Standby power

~ 7 W

~ 7 W

 

Acoustic noise level

< 35 dBA

< 35 dBA

 

 

Standard: RS232

Standard: RS232

Comm. Interface

Optional: RS485

Optional: RS485

 

and others

and others

mechanical

 

 

 

W x D x H (mm)

350 x 302 x 124

350 x 302 x 139

Weight (kg)

12,25

12,5

 

Product specifications are subject to change without notice