Inverter information
Model display | MODEL PV 4600 | Inverter model, xkW inverter | |
|
|
| |
LCD Contrast | CONTRAST | The top menu of LCD contrast | |
setting | |||
|
| ||
LCD contrast setting | SET CONTRAST | Setting the contrast of LCD | |
|
|
| |
LCD display lock | LCD LOCKED | Hold the present display | |
message | |||
|
| ||
Waiting for | RECONNEC- | The time for reconnect to grid | |
reconnect to grid | TIONxxxs | ||
| |||
Firmware version | FIRMWARE xx.xx | F/W version information | |
|
|
| |
Setting Language | SET LANGUAGE | Set up of the display language | |
|
|
| |
LCD display Language | LANGUAGE ENG | Display Language of LCD | |
|
|
|
LED
There are 2 LED’s on Protect PV, one is green and the other is red. Normally, only the green LED switches on during operation. Their indicated status is explained as follows:
1.Power on (green LED): It lights to indicate that Protect PV is running.
2.Fault (red LED): Illuminates during a “fault” or “failure”. Details of possible faults and their solutions can be found in the previous table.