AEG 3009VNM-M, 3009VNMM user manual Warnings, need to be fixed to the wall

Models: 3009VNM-M 3009VNMM

1 34
Download 34 pages 58.86 Kb
Page 7
Image 7
b)For free standing: A non-metallic flexible pipe can be used as long as it complies with current standards and the

b)For free standing: A non-metallic flexible pipe can be used as long as it complies with current standards and the

following installation instructions are observed: the pipe must be longer than 400 mm and shorter than 1500 mm; it must not exceed 50°C in any point; it is not pulled or twisted; it cannot be choked and the entire edges, sharp corners or other similar hazards.

Before connecting the non-metallic flexible pipe, the brass adapter and gasket supplied with the cooker and/or available form the reseller must be fitted to the pipe/gas train on

the back of the cooker. The regulator provided should be positioned between the brass adapter and the non metallic flexible pipe.

c)A certified gas plumber must complete the installation and meet with local regulation requirements for gas connections. Where the unit has an armour cable a certified electrician must complete the electrical connection. The white, or neutral wire will not be used and must be capped using a marrette.

need to be fixed to the wall WARNINGS:

In order to prevent tipping of the appliance, must be installed a stabilized means. Please see the picture. The chain on the back of the range

need to be fixed to the wall

(PLEASE NOTE: The fixing hook is not provided as the type will depend on the construction of the wall to which it will be drilled and fitted. The installer should provide the fixing hook per customer request).

7

Page 7
Image 7