REGULATING THE MINIMUM OUTPUT OF THE HOB BURNERS
Normal/valve taps:
Ignite the burners and turn the knob to the maximum position. Remove the knob and insert a small
N.B. For liquid gas settings, the burner minimum must be set by fully tightening the tap
Fig.8
WARNINGS:
-If the burner flames accidentally go out, turn off the KNOB and wait for at least one minute before igniting.
-Using a gas cooker produces heat and humidity in the room where it is installed. Ensure the room is well ventilated by keeping all the natural air vents open or by installing an extraction hood with flue pipe.
-Intensive or extensive use of the cooker may require supplementary ventilation e.g. opening a window, or more efficient ventilation e.g. increasing the capacity of the mechanic ventilation, if installed.
N.B. When the burners are alight, there must not be any draughts inside the room in that they may affect the flame or even blow it out.
5