Installation and Connection Instructions
Leak Prevention System
For protection from damage due to water leaks, the dishwasher is equipped with a leak prevention system, the AQUA CONTROL SYSTEM.
In the event of a fault, the safety valve immediately interrupts the sup- ply of water to the appliance and the drain pump switches on. By this means water can neither escape nor overflow. The remaining water in the appliance is automatically pumped out.
1The AQUA CONTROL SYSTEM also works when the appliance is switched off – the appliance must however not be disconnected from the mains.
Electrical connection
1In accordance with the conditions of the electricity supply companies in respect of the technical aspects of making connections to the mains, fixed connections to the mains may only be made by approved electri- cians.
When connecting up the appliance, observe the VDE regulations and, if necessary, any additional conditions from your local electricity supplier. Following installation, live parts and wiring insulated during operation must not be accessible using a test finger in accordance with
EN 60335/DIN VDE 0700.
Information on the electrical connection can be found on the rating plate on the inner edge of the dishwasher door on the right. If the appliance has a
Prior to connecting up ensure that the mains voltage and type of sup- ply match the nominal voltage and type of supply given on the rating plate. The required level of protection is also to be found on the rating plate.
To isolate the dishwasher from the mains, pull the mains plug. If the appliance is permanently connected to the mains, then it must be iso- lated from the mains using measures provided in the electrical installa- tion (fuses – unscrew
35