2.Display

2.1.3.Status

 

 

Menu Structure - Status

 

2

 

Display Functions

Description

 

[-] Ambient Conditions

Only applicable if sensors are connected

 

 

Irradiance: 1400W/m2

Irradiance. “NC” if not connected

 

 

PV module temp: 100 oC

PV module temperature. “NC” if not connected

 

 

 

Ambient temp: 20 oC

Ambient temperature. “NC” if not connected

 

 

 

Irr. sensor temp: 20 oC

Irradiation sensor temperature. “NC” if not connected

 

 

[-] Photovoltaic

 

 

 

 

[-] Present values

 

 

 

 

 

[-] PV input 1

 

 

 

 

 

 

Voltage: 1000V

Voltage detected at PV input 1

 

 

 

 

 

Current: 15.0 A

Current detected at PV input 1

 

 

 

 

 

Power 10000 W

Power detected at PV input 1

 

 

 

 

[+] PV input 2

 

 

 

 

 

[+] PV input 3

Not visible if inverter type is 10 kW

 

 

 

[-] Isolation Resistance

 

 

 

 

 

Resistance: 45 MΩ

PV isolation at start up

 

 

 

[-] PV Input Energy

 

 

 

 

 

Total: 369000kWh

Daily production of all PV inputs

 

 

 

 

PV1: 123000 kWh

Daily production of PV input 1

 

 

 

 

PV2: 123000 kWh

Daily production of PV input 2

 

 

 

 

PV3: 123000 kWh

Daily production of PV input 3

 

 

 

[-] PV Configuration

 

 

 

 

 

PV input 1: Individual

Configuration of PV input 1. The configuration is only shown when the in-

 

 

 

 

verter is in Connecting or On grid mode.

 

 

 

 

 

 

 

 

 

 

PV input 2: Individual

 

 

 

 

 

PV input 3: Individual

 

 

 

[-] AC-grid

 

 

 

 

[-] Present Values

 

 

 

 

 

[-] Phase 1

 

 

 

 

 

 

Voltage: 250 V

Voltage on phase 1

 

 

 

 

 

Current: 11.5 A

Current on phase 1

 

 

 

 

 

Frequency: 50 Hz

Frequency on phase 1

 

 

 

 

 

Power: 4997 W

Power on phase 1

 

 

 

 

[+] Phase 2

 

 

 

 

 

[+] Phase 3

 

 

 

 

[-] Residual Current Monitor

 

 

 

 

 

Current: 350 mA

Residual current in mA

 

 

[-] Grid management

Only visible if the inverter is set up for feed-in to medium or high voltage

 

 

 

 

 

 

grid (e.g. _MV country is the selected country)

 

 

 

[-] Power level adjustment

 

 

 

 

 

[-] Present limit: 100 %

Maximum allowed power output in % of nominal power output. “Off”

 

 

 

 

means that the power level functionality has been disabled in the inverter.

 

 

 

 

 

 

 

 

 

[-] Reactive power

Only displayed if the current country setting is an MV country or custom,

 

 

 

 

 

 

and in Protect PV versions.

 

 

 

 

Setpoint type: Off

The setpoint type for Reactive Power. Off means that no internal setpoints

 

 

 

 

are used, but the inverter will accept an external setpoint.

 

 

 

 

 

 

 

 

 

 

Value: -

The current value of the setpoint for reactive power, the unit depends on

 

 

 

 

the selected setpoint type.

 

 

 

 

 

 

Table 2.3: Status

6

8000038784_00_BAL_en / L00410565-01_02

Page 7
Image 7
AEG 8000038784_00_BAL_en user manual Menu Structure Status Display Functions Description