E E P R O M P A R A M E T E R S

Ta b l e 9 : E E P R O M P a r a m e t e r s

Parameter

EEPROM

Length

Range

Default

Description

Address

(Bytes)

 

 

 

 

 

MAC ID

0x80

8

0x00 - 0xFF

 

Factory programmed 8 byte unique IEEE MAC

 

 

 

 

 

address.

 

 

 

 

 

Note: This address is write protected and can-

 

 

 

 

 

not be modified.

 

 

 

 

 

 

Part Number

0x90

16

0x00 - 0xFF

 

Provides part number information. EEPROM

 

 

 

 

 

byte 0x95 can be read to determine device type

 

 

 

 

 

(C, R, or E).

 

 

 

 

 

 

API Control

0xC1

1

0x00 - 0xFF

0xF8

Settings are:

 

 

 

 

 

bit-7: Reserved

 

 

 

 

 

bit-6: Reserved

 

 

 

 

 

bit-5: Reserved

 

 

 

 

 

bit-4: Reserved

 

 

 

 

 

bit-3: Reserved

 

 

 

 

 

bit-2: API Send Data Complete

 

 

 

 

 

0

= Disabled

 

 

 

 

 

1

= Enable

 

 

 

 

 

bit-1: Transmit API

 

 

 

 

 

0

= Disabled

 

 

 

 

 

1

= Enabled

 

 

 

 

 

bit-0: Receive API

 

 

 

 

 

0

= Disabled

 

 

 

 

 

1

= Enabled

 

 

 

 

 

 

RSSI Threshold

0xC8

1

0x00 - 0xFF

 

The minimum RSSI required. Packets received

 

 

 

 

 

with a weaker RSSI than this threshold will be

 

 

 

 

 

discarded.

 

 

 

 

 

 

D.O.B.

0xE0

4

 

 

Provides factory calibration and test date.

 

 

 

 

 

 

 