Read all instructions before installing or using this appliance.
Installation Instructions
Save these instructions for future reference.
Installation Safety Instructions

Warning!

Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information, consult a
qualifi ed installer, service agency, manufacturer
(dealer) or the gas supplier. Never reuse old
exible connectors. The use of old fl exible
connectors can cause gas leaks and personal
injury. Always use NEW fl exible connectors
when installing a gas appliance.

Important

Remove all packing material and literature
from oven before connecting gas and electrical
supply to range.
Have your range installed by a qualifi ed
installer.
• Your range must be electrically grounded
in accordance with local codes or, in the
absence of local codes, in accordance with
the National Electrical Code (ANSI/NFPA 70,
latest edition).
• Before installing your range on linoleum or
any other synthetic fl oor covering, make sure
the fl oor covering can withstand 180°F without
shrinking, warping or discoloring. Do not
install the range over carpeting unless a sheet
of 1/4’’ thick plywood or similar insulator is
placed between the range and carpeting.
• Make sure the wall coverings around the
range can withstand heat generated by the
range up to 200°F.
• Avoid placing cabinets above the range. There
must be a gap of at least 30’’ (76cm) between
the top of the range and any combustible
surface above it.
If a ventilating hood is installed above the range
follow the installation instructions supplied with
the hood.

Caution

Items of interest to children should not be stored
above a range - children climbing on the range
to reach items could be seriously injured.

Converting to LP Gas

This appliance is supplied set for Natural gas.
A conversion kit for Propane gas is supplied with
the range.
If the appliance is to be converted this must be
done before installation. The conversion must
be performed by a qualifi ed LP gas installer.
See the Conversion section at the back of this
installation manual for more details.