Read all instructions before installing or using this appliance.

Installation Instructions

Save these instructions for future reference.

Gas Connection

Installation of this range must conform with local codes or, in the absence of local codes, with the Na- tional Fuel Gas Code, ANSI Z223.1-latest edition. In Canada the range must be installed in accordance with the current CGA Standard CAN/CGA-B149

-Installation Codes for Gas Burning Appliances and Equipment and/or local codes.

In The Commonwealth Of Massachusetts

This product must be installed by a licensed plumber or gas fitter when installed within the Common- wealth of Massachusetts.

A “T” handle type manual gas valve must be in- stalled in the gas supply line to this appliance.

Gas Supply Requirements

Recommended Gas Pipe Outlet Locations

Opening inside the drawer cavity

Provide Adequate Gas Supply

Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and the adjustment of the appliance are compatible.

The range is designed to operate at a manifold pressure of 4’’ of water column on natural gas. A conversion kit for LP gas (propane or butane) is supplied with the range. When converted to LP gas, a pressure of 10’’ of water column is required.

Make sure you are supplying your range with the correct type of gas.

If the range is to be used on LP gas, a qualifi ed LP installer must convert it. We recommend that the range be converted before installation. This must be done before the range can be used on LP gas.

For proper operation, the pressure of natural gas supplied to the regulator must be between 41/2’’ and 13’’ of water column.

For LP gas, the pressure supplied must be between 10’’ and 13’’ of water column.

When checking for proper operation of the regulator, the inlet pressure must be at least 1’’ greater than the operating (manifold) pressure as given above.

The pressure regulator located at the inlet of the range manifold must remain in the supply line regardless of whether natural or LP gas is being used.

A fl exible metal appliance connector used to connect the range to the gas supply line should have an I.D. of 1/2’’ and be 5 feet in length for ease of installation.

Connect the Range to the Gas Supply

Shut off the main gas supply valve before disconnecting the old range and leave it off until the new hookup has been completed. Don’t forget to relight the pilot on other gas appliances when you turn the gas back on.

Because hard piping restricts movement of the range, the use of a CSA International- certified fl exible metal appliance connector is recommended unless local codes require a hard-piped connection.

Never use an old connector when installing a new range. If the hard piping method is used, you must carefully align the pipe; the range cannot be moved after the connection is made.

36

Page 38
Image 38
Aga Ranges U104001-03 manual Gas Connection, Gas Supply Requirements, Connect the Range to the Gas Supply

U104001-03 specifications

The Aga Ranges U104001-03 is a remarkable embodiment of luxurious cooking technology, combining classic aesthetics with modern functionality. Crafted for both culinary enthusiasts and professional chefs, this range is built to elevate the cooking experience in any kitchen setting.

One of the standout features of the U104001-03 is its unique heat retention and distribution system. The range utilizes cast iron cooking technology, which not only retains heat exceptionally well but also distributes it evenly across all cooking surfaces. This ensures consistent cooking results, crucial for baking and roasting. The gentle, even heat allows for the development of complex flavors, making it ideal for creating gourmet dishes.

The U104001-03 offers multiple cooking options with its wide array of burners and ovens. It typically includes several gas burners, providing chefs with precise temperature control for various cooking styles. From simmering delicate sauces to achieving high-heat searing, these burners adapt effortlessly to different culinary techniques.

Another defining characteristic of the Aga range is its iconic design. The U104001-03 boasts a robust, traditional aesthetic that can serve as a stunning centerpiece in any kitchen. Available in an array of vibrant colors, this range allows homeowners to customize its appearance to match their unique style and decor. The enamel finish not only enhances its visual appeal but also makes for easy cleaning and maintenance.

In terms of technology, the Aga Ranges U104001-03 incorporates modern conveniences, such as programmable timers and dual-fuel options, allowing users to seamlessly switch between gas and electric cooking. The electronic ignition system ensures quick and safe lighting of the burners, enhancing user experience.

Safety is also a priority in the design of this range. Features like flame failure devices and automatic shut-off mechanisms provide peace of mind while cooking, making it suitable for families who prioritize safety in the kitchen.

The U104001-03 is engineered for durability, built with high-quality materials that withstand the rigors of daily cooking. Its robust construction ensures longevity, making it a worthwhile investment for cooking aficionados.

In summary, the Aga Ranges U104001-03 is a blend of tradition and innovation, delivering exceptional cooking performance along with stunning aesthetics. Its advanced features and thoughtful engineering make it a centerpiece for any serious cook, providing an unparalleled culinary experience. Whether you're roasting, baking, or simmering, this range is designed to inspire and elevate every meal.