Troubleshooting

Mainly detect:

Whether the compressor wiring is connected correct?

Is time for compressor stopping enough?

Is compressor broken?

Power on the unit

Is stop time of the compressor

 

N

 

Restart it up after 3 minutes

 

 

longer than 3 minutes?

 

 

 

 

 

 

 

 

Y

Does startup fail?

Y

Are the wires for the compressor connected correctly? Is connection sequence right?

NConnect the wires as per the connection diagram

Y

Replace the control panel AP1

N

If the fault is eliminated?

N

Replace the compressor

Y

End

57

Page 57
Image 57
Friedrich MW09C1H, MW12C1H, MR09C1H, MR12C1H manual Troubleshooting