Removal Procedure

4. Remove electric box cover

Unscrew the 2 screws fixing the electiric box. Pull theelectric box upwards and unplug the plug-in line to remove the electric box.

5. Remove axial flow fan

Unscrew the nut and remove the washer fixing the axial flow fan and then pull it out.

6.Remove 4-way valve

Wrap the 4-way valve with wet cloth and unsolder the 4 weld spots of the 4-way valve to remove it.

screws

nut and washer

axial flow fan

4-way valve

weld spots

78

Page 78
Image 78
Friedrich MR09C1H, MW12C1H, MW09C1H, MR12C1H manual Removal Procedure