Troubleshooting

In cool, heat mode, the outdoor unit and compressor will not run.

Controller malfunction (IC20 -

03 broken, creepage of parallel capacitor of relay loop,relay is bro-

ken etc.)

Wire loose or wrong connection

Improper setting of temperature

Change controller

Correctly wire according to the drawing

Adjust setting temp.

Water leakage

Abnormal sound and shake

Drainage pipe blocked or broken

 

 

Change drainage pipe

 

 

 

 

 

 

 

 

 

 

 

Wrap of refrigerant pipe joint is not close

 

 

Re-wrap and make it tight.

enough.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan of indoor unit contacts other parts.

 

 

 

Adjust fan location.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Foreign object in indoor unit

 

 

 

Take out the foreign object.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor shakes too much.

 

 

 

Adjust support washer of compressor, and

 

 

 

tighten loosen screws.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Touch of pipeline of outdoor unit

 

 

Separate the touching pipeline.

 

 

 

 

 

 

 

 

 

 

Touch of inner plates

Louver of outdoor unit touched outer case.

Abnormal sound inside compressor

1.Tighten connect screw.

2.Stick absorbing clay between plates.

Adjust location of louver.

Change compressor