Agilent Technologies E4351B, E4350B service manual Measurement Techniques, 1. Basic Test Setup

Models: E4351B E4350B

1 57
Download 57 pages 1001 b
Page 4
Image 4
Measurement Techniques

Measurement Techniques

Note All tests are performed in the FIXED as shown in Figure 2-1.

Measure the DC voltage directly at the +S and -S terminals.

Set the SENSE switch at the back of the supply to the Remote position.

Connect the remote sensing leads from +OUT to +S, and from -OUT to -S.

Use adequate wire gauge for the load leads as described in Chapter 4 of the Operating Manual.

Basic Test Setup

TO OSCILLOSCOPE

OR RMS VOLTMETER

-

+240 VDC MAX

 

 

IP VP IM IM I P S

S

SET TO

+

-

+ -

+

-

 

REMOTE

 

 

 

 

 

 

LOCAL

 

 

 

 

 

 

REMOTE

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO DVM

120 uF, 100 V

 

 

 

 

 

 

 

 

 

 

CURRENT MONITORING

TO DVM OR

 

 

 

 

RESISTOR

 

 

RMS VOLTMETER

 

 

 

 

(GUILDLINE 0.1 OHM,

 

(CC TESTS)

 

 

 

 

 

 

 

 

 

 

15 A, 0.04%)

 

 

 

 

 

 

 

* USE DC POWER SUPPLY

 

 

 

+

-

 

(SAME POLARITY CONNECTIONS)

 

 

 

 

 

 

 

FOR -CC TEST

*

ELECTRONIC

LOAD

Figure 2-1. Basic Test Setup

4

Service Addendum

Page 4